My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19572
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19572
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 11:01:21 AM
Creation date
1/31/2019 11:01:19 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19572
Building Department - Name
DR HORTON INC
Address
36127 CARRIAGE PINE CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R40&2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Galen El do Builder Name: DRH Express Homes <br /> Street: .3&12r - Pi Ae-6 Permit Office: <br /> City,State,Zip: Zephyrhills,FL, Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa © ( County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2511.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1269.30 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 956.22 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 286.00 ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1451.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1451.00 ft2 <br /> 6. Conditioned floor area above grade(ftz) 2432 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11. Ducts R ft2 <br /> 7. Windows(229.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 231 <br /> a. U-Factor: Dbl,U=0.34 189.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 33.8 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.044 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Floor Types (1451.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1019.00 ft2 EF:0.950 <br /> b. Conservation features <br /> b.Floor over Garage R=19.0 432.00 ft2 None <br /> c.N/A R= ft2 15.Credits <br /> Pstat <br /> Glass/Floor Area:- 0.094 Total Proposed Modified Loads: 72.92 PASS <br /> Total Baseline Loads: 74.48 <br /> I hereby certify that the plans and specifications covered by Review of the plans and a 'tH>r ST,gT� <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance yw �,, "�. __' <br /> with the Florida Energy Code. ,tru.a. ::� •;� �d t <br /> PREPARED BY: Before construction is completed <br /> DATE: II-7 16 this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. COD WE <br /> OWNER/AGEN BUILDING OFFI AL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler a closure qualifies as <br /> certified factory-sealed in accordance with R463.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 1 1/7/201 6 9:22 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.