My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19572
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19572
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 11:01:21 AM
Creation date
1/31/2019 11:01:19 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19572
Building Department - Name
DR HORTON INC
Address
36127 CARRIAGE PINE CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ap�`*`�S3jyF'OjR Manual S Compliance Report Date: Oct 07,2014 <br /> Entire House By: <br /> v•�� Progressive Air Systems <br /> Sft'rEM9.%O <br /> 5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Project • • <br /> For: DR Horton/Express <br /> Lot 20 Blk 1 Silverado, Zephyrhills, FI <br /> C-mling EquiPment, <br /> Design Conditions <br /> Outdoor design DB: 91.2OF Sensible gain: 24535 Btuh Entering coil DB: 76.0°F <br /> Outdoor design WB: 77.1 OF Latent gain: 3250 Btuh Entering coil WB: 63.0°F <br /> Indoor design DB: 75.0OF Total gain: 27785 Btuh <br /> Indoor RH: 50% Estimated airflow: 1120 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NA036****A+FB4CNP036 <br /> Actual airflow: 1120 cfm <br /> Sensible capacity: 26365 Btuh 107%of load <br /> Latent capacity: 4753 Btuh 146%of load <br /> Total capacity: 31118 Btuh 112%of load SH R: 85% <br /> HeatIng Equfpment <br /> Design Conditions <br /> Outdoor design DB: 40.0OF Heat loss: 22889 Btuh Entering coil DB: 69.5°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NA036****A+FB4CNP036 <br /> Actual airflow: 1120 cfm <br /> Output capacity: 30307 Btuh 132%of load Capacity balance: 36 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1120 cfm <br /> Output capacity: 7.5 kW 112%of load Temp. rise: 17 OF <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> i htsoft 2016-Nov-0412:35:24 <br /> wr <br /> ^� g Right-Suite(E)Universal 2013 13.0.11 RSU18520 Page 1 <br /> ACCA ...les\Express homes\Galen 4EGB-3 ton New Code.rup Cale=MJ8 House faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.