Laserfiche WebLink
1239 Jabara Ave; <br /> URNER North Port,FL 34288'J <br /> ENGINEERING & Ph. 941-380-1574 <br /> CONSULTING,INC. FBPE C.O.A.#29779 <br /> Evaluation Report 161D <br /> August 28,2017 <br /> Product Description: Series 8400 PVC Casement Window,Large Missile Impact,DP67.5,37"x 72" <br /> unit size with HS laminated glass, or 37"x 63'unit size with annealed laminated glass <br /> Manufacturer: Custom Window Systems,Inc. 1900 SW 441"Ave,Ocala,Fl, 34474 <br /> Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC <br /> Product Approval Rule Chapter 61 G20-3.005(4). This product complies with the requirements of the 6d' <br /> Edition(2017)Florida Building Code including,the High Velocity Hurricane Zone. The product testing <br /> standards performed are outlined below. <br /> Technical Documentation: <br /> 1) This report,prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port,FL <br /> 2) Approval drawing CWS-161D,signed and sealed by Lucas A.Turner,P.E. <br /> 3) Test Reports NCTL-210-3673-1,-IA,-2,-2A,and NCTL-210-3674-1,-lA,-2,-2A, from <br /> National Certified Testing Laboratories,Orlando,FL signed and sealed by Gerard J.Ferrara,P.E. <br /> a. Testing Performed: TAS 201/202/203 1994,AAMA/WDMA/CSA 101/I.S.2/A440- <br /> 2005,and ASTM E 1886/1996 2002/2005 <br /> 4) Supplemental Calculations to support CWS-161D,signed and sealed by Lucas A.Turner,P.E. <br /> Installation: Units must be installed according to approval document CWS-161D. <br /> Limitations of Use: This product: <br /> 0 May be used in X config.in unit sizes up to 36"x 72"with 1/8"(fIS or Temp.)outboard,-air- <br /> 1/8HS-090PVB-1/8HS laminated inboard glass,or in unit sizes up to 36"x 63"with 1/8"(Ann. <br /> or Temp.)outboard,-air- 1/8Ann-090PVB-1/8Ann laminated inboard glass <br /> 0 Requires outer lite in I.G.to be fully tempered when used in HVHZ above 30 ft of grade <br /> 0 Requires max.glass daylight sizes as shown in CWS-161 D <br /> 0 Achieves design pressures of+/-67.5 psf <br /> 0 Is large missile impact resistant and does not require the use of shutters <br /> 0 May be used in the High Velocity Hurricane Zone <br /> 0 Requires Kuraray(Dupont)PVB Interlayer per Miami-Dade N.O.A.#I 6-1117.02t <br /> 0 Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade NOA#17-0206.1 Ot <br /> t I have evaluated the materials in these NOAs and find that they comply with the requirements of the <br /> 6d'Ed.(2017)Florida Building Code for use in this product. <br /> Certification of Independence: I.do not have,nor do I intend to acquire,nor will I acquire, a financial <br /> interest in Custom Window Systems or in any company manufacturing or distributing products for which <br /> this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire, a financial interest <br /> in any other entity involved in the testing or approval process of this product. <br /> tIOREW 90 <br /> Lucas No 5S201 <br /> 8/28/2017 <br /> Turner <br /> it Lucas A. Turner,P.E. <br /> 2017-08-30 STATE OF "'w <br /> FL PE#58201 <br /> 16:01+20:00 <br />