SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19586
Building Department - Name
D R HORTON INC
Address
6549 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Cali 1828 Elev D ff Builder Name: DRH Ex ess Homes <br /> Street: 4. ` Permit Office: <br /> City,State,Zip: ZephyZliills, FL, S�ly Permit Number: <br /> Owner: �l(2 Jurisdiction: 151 <br /> Design Location: FL,Tampa v' County:: Pasco(Flonda Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family, a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2 <br /> b. Frame-Wood,Adjacent R=11.0 306.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1828.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1828.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: - SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average.Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallonsEF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads: 61.11 PASS <br /> Total Baseline Loads: 61.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ATE STq�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> O _ - O.t• <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. rrrr° ��•: ;•°��ti,�O <br /> PREPARED BY: L'Nti Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 * ° <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy <br /> OWNER/AGENT: BUILDING O IC AL: <br /> DATE: DATE: 001 <br /> - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 11/11/2017 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />