Laserfiche WebLink
Manual S Compliance Report Job: <br /> - - wrightsofto P p Date: Oct 10,2014 <br /> Entire House By: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Project • • <br /> For: DR Horton/Express <br /> Lot 25 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 20798 Btuh Entering coil DB: , 75APF <br /> Outdoor design WB: 77.1 OF Latent gain: 2966 Btuh Entering coil WB: 62.7°F <br /> Indoor design DB: 75.0°F Total gain: 23764 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP. <br /> Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23270 Btuh 112%of load <br /> Latent capacity: 3914 Btuh 132%of load <br /> Total capacity: 27184 Btuh 114%of load SHR: 86% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 <br /> Actual airflow: 1000 cfm - <br /> Output capacity: 25604 Btuh 121%of load Capacity balance: 32 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm <br /> Output capacity: 6.6 kW 1070/6 of load Temp. rise: 20 OF <br /> Meets are all requirements of ACCA Manual S. <br /> wri htsofta 2017-Nov-11 13:07:37 <br /> 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> �� ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup, Calc=MJ8 House faces:NE <br />