Project Summary Job: <br /> -�- wrightsoft" Date: Oct 10,2014 <br /> Entire House By: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Proiect Information, <br /> For: DR Horton/Express <br /> Lot 25 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> Notes: <br /> Design Inf6rmation <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside.db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 17539 Btuh Structure 16200 Btuh <br /> Ducts 3561 Btuh Ducts 4598 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 21100 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 20798 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2360 Btuh <br /> Ducts 606 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 1820 1820 Equipment latent load 2966 Btuh <br /> Volume(ft3) 16012 16012 <br /> Air changes/hour 0.26 0.14 Equipment total load 23764 Btuh <br /> Equiv.AVF(cfm) 69 37 Req. total capacity at 0.75 SHR 2.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade . CARRIER <br /> Model. CH14NB030****A Cond CH14NB030****A <br /> AHRI ref Coil FB4CNP030 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh @ 47OF Latent cooling 7500 Btuh <br /> Temperature_rise 27 OF Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.047 cfm/Btuh Air flow factor 0.648 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat. Load sensible heat ratio 0.88 <br /> Capacity balance point=32 OF <br /> Backup: <br /> Input=7 kW, Output=22477 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> WI'1 I1tS0ft° 2017-Nov-1113:07:37 <br /> g Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> /R. ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:NE <br />