Laserfiche WebLink
FLORIDA ENERGY EFFICIENCY CODE <br /> FOR BUILDING CONSTRUCTION <br /> Envelope Leakage Test Report <br /> Prescriptive and Performance Method <br /> Project Name: SILVERADO Builder Name: D R HORTON / I <br /> Street: 6549 Wagon Trail St Permit Office: C( r �P-AVrh"t(S <br /> City,State,Zip: Zephyrhills,FL 33541 Permit Number: <br /> Design Location: 6549 Wagon Trail St(Lot 25) Jurisdiction: (Q C &OD <br /> Cond.Floor Area: 1828 Cond.Volume: 16086 <br /> Envelope Leakage Test Results Leakage Characteristics <br /> Regression Data: <br /> C: n: R: <br /> CFM(50): 1661 <br /> Sin le or Multi Point Test Data <br /> ELA: 91 <br /> HOUSE PRESSURE FLOW: <br /> 1 50 Pa 1661 cfm EgLA: 216 <br /> ACH: 6.2 <br /> 2 0 Pa 0 cfm <br /> SLA: .05 <br /> 3 0 Pa 0 cfm <br /> 4 0 Pa 0 cfm ACH(50)': 6.2 <br /> .For prescriptive projects,tested leakage must be—7 <br /> 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage <br /> must be—the ACH(50)shown on Form R405-2014 <br /> 6 Pa cfm for this project. <br /> R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 <br /> and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in <br /> Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the <br /> results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all <br /> penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration <br /> 3.Interior doors,if installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be tumed off;and <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> I hereby certify that the above envelope leakage performance results <br /> demonstrate compliance with Florida Energy Code requirements in <br /> accordance with Section R402.4.1.2. <br /> Testing shall be conducted by either individuals as <br /> defined in Section 553.993(5)or(7),Florida Statutes 0,1-IRE5r9r� <br /> or individuals licensed as set forth in Section �� o €: <br /> 489.105(3)(f),(g),or(i)or an approved third party.A <br /> written report of the results of the test shall be signed n � <br /> Digitally signed by Michael by the third party conducting the test and provided to y"ji } <br /> Silberstein the code official. i�o <br /> Date:2018.08.2810:49:33 EDT Z <br /> CN=Michael Silberstein,O=TopBuild •lN (' <br /> Home Services,OU, G'Op we— <br /> EMAI LADDRES S=Mich ael.S ilb erste i <br /> Signature: n@topbuild.com,C=US I <br /> Printed Name: <br /> Michael Silberstein BUILDING OFFICIAL: <br /> Date: 08/28/2018 DATE: <br /> Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. <br /> 10/25/2017 <br /> 391905 <br />