My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19587
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19587
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 11:14:25 AM
Creation date
1/31/2019 11:14:22 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19587
Building Department - Name
D R HORTON INC
Address
6557 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 2605 Elev C Builder Name: HE <br /> Street: Permit Office: <br /> City,State,Zip: Z L S35t_� Permit Number: fit <br /> Owner: Jurisdiction: tZ <br /> Design Location'. FL,Tampa County:: Pasco(Florida Climate Zone 2). <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 scift.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.30 ft2 <br /> b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2 <br /> 3. Number of units,if multiple family I c.Frame-Wood,Adjacent R=1 1.0 332.22 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 <br /> 6. Conditioned floor area above grade(W) 2605 b.N/A R= ft2 <br /> Conditioned floor area below grade(W) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(250.0 scift.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,U=0.34 210.00 ft2 <br /> SHGC: SHGC=0.31 12.Cooling systems kBtu/hr Efficiency <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.052 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (1541.0 scift.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=O.O 1104.00 ft2 b. Conservation features <br /> b. Raised Floor R=19.0 437.00 ft2 None <br /> c.N/A R= 1 ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.096 Total Proposed Modified Loads: 79.42 PASS <br /> Total Baseline Loads: 79.15 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ST_ <br /> this calculation are in compliance with the Florida Energy specifications covered by this 0 <br /> ffs Code. calculation indicates compliance =�;9z <br /> 4: <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed W <br /> DATE: this building will be inspected for 0 -7. <br /> compliance with Section 553.9108 .. ......... <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Co elr- SOD WE <br /> OWNER/AGENT- BUILDING OFFICIAL: <br /> DATE: DATE: <br /> Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1-2. <br /> - Compliance with a proposed duct leakage Qp requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESINET Standards,is not greater than 0.060 Qn for whole house. <br /> 11/11/2017 12:48 PM EnergyGaugeg USA-FIaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.