18-19588
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19588
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 11:15:41 AM
Creation date
1/31/2019 11:15:39 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19588
Building Department - Name
D R HORTON INC
Address
6597 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- FORM 9405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Cali 1828 Elev C Builder Name: DRH E re s ome ( S <br /> Street: �� W en-Tr O J ,Permit Office: Ct � k <br /> City,State,Zip: ZephyThills,FL,3-jGH 1 Permit Number: <br /> Owner: /(/�\I� Jurisdiction: (e tk6q) <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3, Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1828.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1828.00 ftZ <br /> 6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(166.5 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sgft.) Insulation Area a.Electric Cap:50 gallonsEF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads: 60.06 PASS' <br /> Total Baseline Loads: 61.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 'SKET.gT <br /> this calculation are in compliance with the Florida Energy specifications covered by this 0� <br /> Code. calculation indicates compliance cq yip `' `''��•����16, <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed r •- <br /> DATE: 11-11-17 this building will be inspected for O IV' <br /> compliance with Section 553.908 * x <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Cc GOD W11E. <br /> OWNER/AGENT: BUILDING FI IA <br /> DATE: - DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test iieport in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 On for whole house. <br /> 1 1/1 1/2017 1:13 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.