Sin le Famil Dwe11' <br /> g Y - g <br /> Plan Review Coinrrients <br /> 1: K.F. X. shall lie.a rriinirnuin of.8" above the road elevation and an engineered site plan. - <br /> 2.' Lots.shall be graded to comply with R401.3 of the F.B:.C. <br /> 3. Compaction test required.if 24" or more of fill dirt is brought in at any one place: <br /> 4'. Tie in survey required before pouring concrete. <br /> y q .. . <br /> 5.: Drive s:re uire a R.O.W. use permit:' All 4 sides of driveway thru the sidewalk shall-ha, <br /> expansion material: <br /> '6.. All.setbacks shall be inet.,. . <br /> .7.: :All.property markers shall be uncovered and marked at time of first inspection: <br /> -.. . <br /> 8:. All A.D.A:requirements shall be met..'- <br /> 9.: No,electric, plumbing,mechanical, or framing shall be covered without an,inspection and <br /> approval first. <br /> 10. All.Garages shall.comply mith.section R302:6:of the F.B.C::(Fire Separation).: <br /> . 11. Appliances'shall iiot:be installed in.a locationwhere subjectto.mechanical dam,age unless :. . <br /> protected by approved barriers: M303-.4 of the F.B.0 <br /> . . <br /> 12. Water heaters shall comply with section P607,3 of the F.B.C. <br /> 13. Foundation supports for A/C.units shall be raised at least 3 above finished grade.. M1308.1 <br /> 14. Return airin all-bedrooms. F.B.C. ,M,1620.4 <br /> 15: Smoke detectors-are to be installed:in accordance with:R313:.1 of ihe:F.B.C. <br /> .16: All glazing requirements are:.to be in accordance with R308.4 of the F.B.C. . <br /> 17. All means,of egress are to:be in.accordance with R31 L:of the F.B.G. <br /> 18.-`.`Green gypsum board shall not be used:as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19.Combination-type <br /> AFCI breakers are required:at all locations requiring an AFCLtype breaker: <br /> 20. Carbon monoxide alarins will be required in.now.construction that uses-fossil-burning-heating <br /> or appliances or an attached garage.. They shall be,installed in accordance with,the F.B.C:: <br /> 21. All plumbing, mechanical, And electrical shall-be separate from unit.to:unit: This all. <br /> underground plumbing and electric: <br /> 22. All 2011:N.E:C: Codes will be enforced: <br /> 23. Tamper=Resistant Receptacles in accordance with 406.1.1-of the 2011 ME:C <br /> 24:.In accordance.with the Land Development:Code;dots shall be sodded before final of leash 10. . . . <br /> feet'around the structure. <br /> 25.A copy of the energy cacls shall be with permit-at all times. <br /> 26. Cony of final insulation report shall be.provided with.p6-mit before.friar <br /> F:F:E.-Finished Floor Elevation <br /> F.B.C_ Florida Building Code 6th Edition: <br /> R.O.W. Right.of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric:Code(2011) . <br />