Laserfiche WebLink
I <br /> Single _Family Dwelling <br /> Plan Review.Comrrients <br /> 1: .F.F:E. shall be a minimum of.8"above.the road elevation and an engineered site plan. <br /> 2. -Lots-shall be graded.to.comply with R401.3 of the F.B:C. <br /> 3. .Compaction:test required if 24" or more of fill dirt is brought in at any one place. . <br /> :.4. :Tie in survey required before pouring concrete.. <br /> 5.. Driveways require a R;O.W. use permit: All 4,sides of driveway thru the sidewalk shall have <br /> expansion material:. - <br /> 6- All setbacks.shall be,met... . <br /> .7.: All.property markers be.uncovered and marked.at time of first.inspection: - <br /> 8 All A.D.A.-requirements.shall be met.: . <br /> 9.: .No:electric;plumbing,mechanical;_or framing shall be covered without an,inspection-arid <br /> approval first. <br /> 10. All Garages shall:comply,with:section R302:6 of the F.B.C,::(Fire S:eparation).. <br /> 11: Appliances shall iiot:be installed in a location where subjectto.rnechariical damage unless. <br /> .protected:by approved barriers. M303-.4 of.the F.B:C <br /> 12. Water heaters shall comply:with section.P607.3 of the F.B.C: <br /> 13. Foundation supports:forA/C units.shall be raised at least 3"above finished"grade,. M1308.1 - <br /> 14. Return air in all.bedrooms..F.B.C. ,M,I620.4, <br /> 15. Smoke detectors'are to be iristalled:iri accordance with R313:1 'of the F.B,C. <br /> 16:.All glazing requirements are.to be in accordance with R308.4.of the F.B.C. . <br /> 17. All means of egress are to be in-accordance with R31 Lof the R.B.C. <br /> 18. `.`Green gypsum board" shall riot be used as.a backer iri showers'ortubs. R702.4:2.F.B.C. <br /> 19. Combination-type-AFCI breakers are.reguired.at all,locations requiring an AFCI,type breaker: <br /> 20: Carbon monoxide.alarms Will be required in new-construction that-uses fossil-burning:heating <br /> or appliances or an attached garage: They shall be.installed in accordance with the F,B.C: . <br /> 21. All plumbing,mechanical,'and electrical shall be separate from unit to:unit: This includes all <br /> ad elecfiunderground:plurin c: <br /> 22. All 2011:N:E.C: Codes will be enforced: <br /> 23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 N.E:C <br /> 24: In accordance..with the Land.Development.Code;lots shall be sodded before final at least 10 <br /> feet around the structure: <br /> 25 A.copy of the energy cacls shall be-with wermitat all times. <br /> 26.Copy of final insulation report shall be.provided with.permit before.finab <br /> F:F-E.-Finished Floor-Elevation <br /> F.B:C-Florida Building.Code 6t'Edition <br /> R.O.W.-Right of Way- <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric:Code.(2011) <br />