Laserfiche WebLink
I <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of--Business and Professional Regulation - Residential-Performance Method' <br /> Project Name: Cali 1828 Elev C Builder Name: DRH Express Homes <br /> Street: 0- a- ,/! �[=1,J J 1 Permit Office: <br /> City,State,Zip: Zephyrhills, FL, c i 1 4 Permit Number: <br /> Owner: - I r ( � Jurisdiction: <br /> Design Location: FL,Tampa IZ\11 County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insui,Exterior R=4.1 1404.00 ft2 <br /> b. Frame-Wood,Adjacent R=11.0 306.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number.of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1828.0 sqft,) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1828 b.N/A- R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11. Ducts R ft2 <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14. Hot water systems <br /> B. Floor Types (1828.0 sg a.Electric Cap:50 gallons <br /> ft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> ���� <br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads: 61.51 <br /> Total Baseline Loads: 61.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and T%ES. <br /> this calculation are in compliance with the Florida Energy specifications covered by this , O <br /> Code. calculation indicates compliance ��v,;, %s "4z . <br /> with the Florida Energy Code. <br /> PREPARED BY: 1,1& ,�,,;., Before construction is completed <br /> DATE: n-g-n this buildingwill be inspected for - � - ,Cf <br /> p � 1 a . <br /> compliance with Section 553.908 <br /> I hereby-certify that this building, as designed,is in compliance Florida Statutes. - ' S� <br /> with the Florida Energy Code.. 1117WE <br /> OWNER/AGENT,�- 1pl BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. - <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 11/9/2017 10:58 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />