My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19598
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19598
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 11:21:22 AM
Creation date
1/31/2019 11:21:20 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19598
Building Department - Name
LENNAR HOMES LLC
Address
6630 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> i <br /> __._.. ��.�...�._.._...-_ _���.�„���,.eza.a-_e.•wtisit.r1•a+EtT.i�F;Bb'.c.•�6raTi.'.'ti:.'D.�ii �i.,a�..�---• <br /> c . <br /> � M <br /> When Buildings Talk,Wa Liston. <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING <br /> CONSTRUCTION <br /> Envelope Leakage Test Report <br /> Prescriptive and Performance Method <br /> Project Name: (a 6 Builder Name: <br /> Street: 63b W0.9 Permit Office: <br /> City,State,Zip: Q�hyrh:ll 33s'i f (-'C Permit Nu er: �QSCie <br /> Design Location: Jurisdictio <br /> I <br /> Envelope Leakage Test Results i <br /> i <br /> Single Point Test Data: <br /> HOUSE PRESSURE: - 5-0 FLOW: <br /> e <br /> Leakage Characteristics <br /> CFM(50): � � Pass Fail <br /> 19 <br /> ACH(50): 533 <br /> R402A.1.2 Testing. The building or dwelling unit shalt be tested and verified as having an air leakage rate of not exceeding 7 air <br /> changes per hour In Climate Zones 1 and 2 ...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 <br /> Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7). Florida Statutes or individuals <br /> licensed as set forth in.Section 489.105(3)(f),(g),or()or an approved third party.A.written report of the results of the test shall be <br /> signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all <br /> penetrations of the building thermal envelope. <br /> . 1.Exteriorwindows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other <br /> Infiltration control measures; <br /> ( 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended. ; <br /> infiltration control measures; <br /> 3.Interior doors,if installed at the time of the test,shall be open; , <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> S.Heating and cooling systems,if Installed at the time of the test,shall be turned oft;and <br /> t <br /> 6.Supply and retum registers,if Installed at the time of the test,shall be fully open <br /> . I hereby certify that the above envelope leakage Where required by the code official, testing shall be <br /> performance results demonstrate compliance with, conducted by an approved.third-party. A written report of <br /> Florida Energy Code requirements in accordance with the test results shall be signed by the third party <br /> t section 11402.4.1. . conducting the test and pro ' ed to the code official. <br /> SIGNATURE: <br /> PRINTED NAME: y� BUILDING Fri <br /> yv <br /> DATE: 101, 018 L DATE: <br /> Testing was conducted in accordance with ANSIIRESNETIiCC 380 to mlist thet20117 residential energy code. <br />
The URL can be used to link to this page
Your browser does not support the video tag.