Laserfiche WebLink
Single Singlef ami y we ing <br /> P v Plan Re View Comments <br /> 1: Y.F.-E. shall be.a.minimum of 8",above.the road elevation and an-engineered site plan. : -- - . <br /> 2. Lots shall-be graded.to comply with R401.3 of the F.B.C. <br /> 3. :Compaction test required:if 24"'or more of fill dirt is.btbught•in at any:one place: <br /> 4. .Tie in survey required before pouring concrete. <br /> 5.. Driveways:require a R.O.W. use permit.. All 4 sides of driveway thru the sidewalk shall.have. <br /> expansion material: <br /> 6.. All setbacks shall be met. <br /> -7. All.property markers shall be uncovered and marked at time'of first 'inspection: <br /> 8. All A.D.A. requirements shall be met.:. <br /> 9. No electric;plumbing,-mechanical;-or-raining shall be covered without an inspection and <br /> approval-first. : . <br /> 10. All Garages shall-comply.with:section R302:6 of,the.F.B.0 (Fire Separation).. <br /> 11.Appliances shall not be installed in.a location where siibjectto_ineehanical damage unless. ' <br /> protected.by approved barriers. :M303.4 o£the F.B:C <br /> 12. Water heaters shall comply with sectionT607.3 of the F.R.C. <br /> 13.-Foundation supports'for A/C.units shall be raised at least 3" above finished grade,. M1308.1 <br /> 14. Return air in all bedrooms.F.B.C. M1620.4,. <br /> 15. Smoke detectors are.to be installed in accordance:with:R313.1 of the F.B.C. <br /> 16: All glazing requirements are.to be in accordance with R308.4 of the F.B:C. <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.G. . <br /> 18. `.`Green gypsum board" shall not be used-as.a backer in showers or tubs. R702.4.2.F.B.C. <br /> 19. Combination-type AFCI breakers_are-required at all.locations requiring an AFCI.type breaker: <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage.:. They shall be.installed in accordancewith-tlie F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to:unit: This includes all <br /> underground plumbing and electric: <br /> 22. All 2011.N.E.C: Codes:will be enforced: <br /> 23. Tamper- Resistant Receptacles in accordan.ce with 406.11 of the 2011 ME <br /> :C <br /> 24:.In accordance.with the Land Development.Code, lots shall be sodded before final at least 10 <br /> feet:around the structure: <br /> 25. A cony of the energy cacls shall be with,permit at all thnes <br /> 26 Cony of final insulatioiz renbrt shall be.prbvided with permit before.fnaL <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code'6t'Edition <br /> R.O.W.-Right of Way <br /> A.D,A.-Americans with Disabilities Act . N.E.C.-National Electric.Code(2011). <br />