Page 5 of 7
<br /> ® MICROMATIC®STANDARD
<br /> V A A RESPONSE PENDENT
<br /> SPRINKLER VK102 (K5.6)
<br /> The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058
<br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com
<br /> Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com
<br /> Approv;A Chart 2',(FM),
<br /> Temperature
<br /> K EY
<br /> Micromatic®;Standard Response Rendent'Sprinkler VK102, �Finish
<br /> Maximum.175 PSI:(12 bar)VWVP' A1x+°Escucch¢onprapproahlej
<br /> Sprinkler Base SIN Thread Size Nominal K-Factor Overall Length FM Approvals'
<br /> Part Number4 NPT BSP U.S. I metric' I Inches I mm (Refer also to Design Criteria below.)
<br /> Standard Orifice
<br /> 12987 VK102 1 1/2" 15 mm 5.6 80.6 2-1/T 57 All,B2,C3,D1,E4,G1Y,G4Z
<br /> 12989 VK102 - 15 mm 5.6 80.6 2-1/4" 1 57 All,B2,C3,D1,E4,G1Y,G4Z
<br /> 10139 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 All,B2,C3,D1,E4,G1Y,G4Z
<br /> 10173 VK102 -- 15 mm 5.6 80.6 2-1/4" 57 All,B2,C3,D1,E4,G1Y,G4Z
<br /> 18020 VK102 1/2" 15 mm 5.6 80.6 2-1/4' 57 Al,B2,C3,D1,G1Y
<br /> Approved Temperature Ratings
<br /> A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79
<br /> °C), 200 °F (93 °C), 212 °F (100 °C),
<br /> 286'F(141 °C),and 360°F(182°C) Approved Finishes Approved Escutcheons
<br /> B-135°F(57°C), 155°F(68°C), 175°F(79°C),200°F 1 - Brass, Chrome, White Polyester', and Y - Standard surface-mounted escutch-
<br /> (93°C),and 212°F(100°C) Black Polyester4 eon or the Viking Microfast® Model F-1
<br /> C-286°F(141 °C) 2-Wax-Coated Brass(corrosion proofing) Adjustable Escutcheon or recessed with the
<br /> D-500°F(260°C)5 3 - High Temperature 200 °F (93 °C) Wax Viking Micromatic@ Model E-1, E-2, or E-3
<br /> E-155°F(68°C), 175°F(79°C),200°F(93°C),286°F Coating (corrosion proofing); maximum am- Recessed Escutcheon
<br /> (141 °C),360°F(182°C),and 500°F(260°C)5 bient temperature allowed at the ceiling = Z- Standard surface-mounted escutcheon
<br /> 150°F(65°C) or re- cessed with the Viking Micromatic®
<br /> F- 135 °F (57 °C), 155 7 (68 °C), 175 °F (79 °C), and 4-ENT6 Model E-1
<br /> 200°F(93°C)
<br /> G-155°F(68°C), 175°F(79°C),and 200°F(93°C)
<br /> Footnotes
<br /> Base part number is shown.For complete part number,refer to Viking's current price schedule.
<br /> 'Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0.
<br /> 'This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals.
<br /> 4 Other colors are available on request with the same Approvals as the standard colors.
<br /> 5 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F(149°C).
<br /> Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300°F(149°C),the response time of the Ultra-High
<br /> temperature rated sprinkler may be severely retarded.
<br /> a FM approved as corrosion proofing for corrosive environments.
<br /> DESIGN CRITERIA =,FM,.•
<br /> (Also-refer to'Approval Chart 2.)
<br /> FM Approval Requirements:
<br /> The Viking Micromati&Standard Response Pendent Sprinkler VK102 is is FM Approved as standard response Non-Storage pendent sprinkler as
<br /> indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data
<br /> Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply
<br /> requirements,hydraulic design,ceiling slope and obstructions,minimum and maximum allowable spacing,and deflector distance below the ceiling.
<br /> NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria.
<br /> IMPORTANT:Always refer to Bulletin Form No. F 091699 -Care and Handling of Sprinklers.Also refer to page F_080614 for
<br /> general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest
<br /> edition of Viking technical data,the appropriate standards of NFPA, FM Global,LPCB,APSAD,VdS or other similar organiza-
<br /> tions,and also with the provisions of governmental codes, ordinances, and standards,whenever applicable.
<br /> Form No. F_031414 17.08.31 Rev 17.1