3920 Watt to 10080 Watt DC Photovoltaic System Electrical Diagram <br /> Solaredge SE 760OA-US Inverter with <br /> OOO One to Two strings of Solarworld SW280 Modules and Solaredge P300 Optimizers <br /> To verter Optional Supply Side Connection Maximum 18 modules per <br /> NEC 705.12A Solarworld 10 string and minimum 8 modules <br /> L+ SW280 SW p1a per string as per Solaredge <br /> N M Modules <br /> 280 ������#s bare copy olaredge P300 <br /> GEC (3)#6 utility meter ower Op timizers <br /> THHNrrHWN-2 zaop - <br /> 314"PVC condu < (4)#10 AWG PV wire 2-B,2-R Module power ptimizer <br /> so A fused (1)#6 Bare Copper I Faca Facto Cable <br /> disconnect with DC e ds Solarworld SW280 <br /> 40Afuses eastag MafnDistribution Module Specs <br /> ej ,o panel Solaredge P300 Power Optimizer <br /> SW Max input power:300 Wp-dc Pmax:280Wp <br /> Y80 #8 Max.Input DC Voltage:48 VDC Voc: 39.5 V <br /> 200A Panelboard Max Input current: 12.5A Vmpp:31.2 V <br /> with 200A main MPPT Range.8-48 VDC Isc: 9.71 A <br /> Max output Voltage.60 VDC Im 9.07 A <br /> breaker Max Output current: 16A pp' <br /> O200A-2 Notes: All work to meet or exceed NEC 2011 <br /> Olunction box to be located within the array boundary. Junction box must be minimum Noma 311 UL listed <br /> O OO enclosure.Free air conductors must be installed in raceway if readily accessible as per 690.31(A).(4)#10 AWG THHN/THWN-2 Orhe minimum volume of the Noma 311 enclosure for the transition of PV wire to THWN-2 wire shall be <br /> O (1)#8 AWG THHN/THWN-2 42 cubic inches. Heyco 5 wire Masthead gland seals or similar connector are required as strain relief <br /> Nema 3R 2-B,2-R,1-G for PV wire into Noma 311 junction box at array. <br /> O 40A/2 Junction 3!4"EMT,FMC(inside structure) Ointerconnection with 40 Amp 2 pole OCPD via 2011 NEC 705.12(D)(2)Load Side Connection. The 40 A <br /> Box LFNC,PVC(outside structure) backfed breaker must be located at the opposite end of the bus from the 200 A main supply breaker <br /> i <br /> 690.31E 4O.The required PV Backfed breaker plus the main breaker rating must be less than or equal to 120%of <br /> the Main service bus rating. 705.12(D)(2) <br /> ' Solaredge SE760OA-US bOOptional Supply Side connection via 705.12A using parallel line taps in a NEMA 311 box(as required) <br /> Transformerless Inverter with <br /> i Dc using NSI IPCS4002, llsco IPC-KUP-L or NSI Tork IPLD 310-3 Multi-Tap Connector or equivalent. <br /> existing n Ac integrated DC disconnect. OPV service disconnecting means for"optional"supply side connection must have neutral/EGC bond <br /> grounding ! Lt1 within and must be listed as"suitable for use as service equipment." 230.66 <br /> electrode ; ! (4)#8 AWG THHN/THWN-2 OThe fuses in the disconnect for the"supply side"option must be rated to handle the maximum short- <br /> 1-B,1-R,1-W,1-G <br /> circuit current available at the supply terminals.110.9,110.10 Over-current protection for the supply side <br /> 3/4"EMT,FMC LFNC <br /> A ; connected conductors shall be located within 10 feet of the connection to the service. 705.31 <br /> 0 0 or PVC 8OI he following label is required on meter can and main panelboard"Service <br /> 4' is fed from dual power sources.Utility and Photovoltaic system" <br /> ' 8. 'PV input Do not relocate this OCPD"label required adjacent to backfed breaker. 705.12(d)(7) <br /> (4)#8 AWG THHN/THWN-2 10 Bonding of module to rail and module to module accomplished through WEEB <br /> 1-B,1-R,1-W,1-G washers or self grounding mid-clamps. <br /> 3/4"EMT,FMC,LFNC,or PVC S.-Warning:DC conductors of this system are ungrounded and may be energized"required on the <br /> DC Disconnect 690.35F <br /> 12.."Warning:Photovoltaic Power Source"label required on conduit per 690.31 (E)(3)(4) <br /> 13.Total voltage drop%for all circuits based on listed conductors is 1.64%based on: <br /> A 100 foot round trip en PV wire o air run to Noma 3R junction box <br /> If required by Utility p <br /> 60A 240V AC Disconnect with label, 11 B.150 round trip source circuits(THWN-2)to termination in DC disconnect <br /> On-site Utility Generation C.30 feet round trip Inverter Output circuit to point of interconnection. <br /> Disconnect Switch DC Disconnect Label D.Conductors should be sized for max 2%voltage drop to decrease possible <br /> Requirements inverter shutdown and production losses due to AC voltage rise at the inverter. - <br /> Vmpp 350 vdc <br /> PV AC Disconnect Label Requirements Vmax 500 vdc fdivided <br /> mula to figure IMPP for DC Disconnect <br /> Operating Current: 32A Impp 11.2 to 23 A(based on array l STC DC power rating of array in Watts <br /> Operating Voltage: 240V nameplate rating) by 360 Vdc equals IMPP in Amps. <br /> Imax 15 or 30 A (1 or 2 strings) 920 wattsl350 Vdc=11.2 Amps <br />