Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1791A1 sf ADS Builder Name: Lennar Homes <br /> Street: 6652 Wagon Trail Street Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL, Permit Number: <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1817.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor: Dbl,U=0.54 87.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.07 PASS <br /> Total Baseline Loads: 58.15 <br /> hereby certify that the plans and specifications covered by Review of the plans and ;a 'THE'STA� <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code.Dave <br /> PREPARED BY: /,/rich Before construction is completed <br /> DATE: this buildingwill be inspected for <br /> P t771 <br /> compliance with Section 553.908 * �_• <br /> herebycertify that this building,as designed, is in compliance Florida Statutes. N <br /> fY 9� 9 P -.,: . �, <br /> with the Florida Energy Code. <br /> OWNER/AGENT: BUILDING OF ICIAL: <br /> DATE: DATE: 7-- i <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. <br /> 2/1/2018 7:00 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 <br />