Laserfiche WebLink
r e <br /> Manual S Compliance Report Job: 1791A1 sf ADS <br /> p p Date: 2/1/2018 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and-Air <br /> Project I • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.30F Sensible gain: 22596 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.3°F Latent gain: 3525 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 26122 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230"++TDR <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 25500 Btuh 113% of load <br /> Latent capacity: 4500 Btuh 128% of load <br /> Total capacity: 30000 Btuh 115% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions 11 - <br /> Outdoor design DB: 30.8°F Heat loss: 25667 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR <br /> Actual airflow: 1000 cfm <br /> Output capacity: 26000 Btuh 101% of load Capacity balance: 31 of <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1000 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets are all requirements of ACCA Manual S. <br /> -ELL <br /> wri htsoft° 2018-Feb-0106:48:45 <br /> I. 9 Right-Sufte®Universal 2017 17.0.23 RSU05714 Page 1 <br /> 14C(:�k ...CBA27UHE AH's\1791A sf ADS template 2.5ton.rup Calc=MJB Front Door faces: W <br />