Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minimum of 8" above.the road elevation and an engineered site plan. <br /> 2.- Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. -Compaction test required if 24' or more of fill dirt is brought in:at any one place: <br /> 4: Tie in survey required before pouring concrete. <br /> 5. -Driveways:require a R.O.W. use permit. All 4:sides of driveway thru the sidewalk shall have . <br /> -expansion material: <br /> 6. All setbacks.shall be met.; <br /> 7.. All property.markers shall be.uncovered and marked at time of first-inspection: <br /> 8. All A.D.A. requirements shall:be met. . <br /> 9. No electric,plumbing, mechanical, or(framing shall be covered without an inspection and <br /> approval first. . <br /> I O.A.11. Garages shall.comply.with section R302:6 of the F.B.C. (Fire Separation). <br /> 11. Appliances.shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.R.C. <br /> 13. Foundation supports_for A/C units shall be raised at least 37 above_ finished grade. M1309.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620A. <br /> 15. Smoke detectors are.to be'installed in-accordance with:R313:1 of the.F.B.C. <br /> 16::A11 glazing requirements are.to be in accordance with R308.4.of the F.B:C. <br /> 17. All means of egress are'to.be in accordance with R31 L-of the F.-B.C. <br /> 18. `.`Green gypsum board" shall not be used as.a backer in showers or tubs.R702.4:2.F.B.-C. <br /> 19. Combination-type AFCI breakers are required,at all locations requiring an AFCI type breaker. <br /> 20. Carbon-monoxide alarms will.be required in new construction that uses fossil-burning heating <br /> or appliances or-an attached garage: They <br /> ; shall be instahed in accordance with the F.B.C.. <br /> 21. All plumbing mechanical,'and electrical shall be separate from unit to unit. This includes all. <br /> underground plumbing and electric: <br /> '22. All 2011.N:E:C: Codes'will.be enforced: <br /> 23.Tamper- Resistant Receptacles in accordance with 40.6.11 of the 2011 N:E:C <br /> 24:.In accordance.With the Land.Development Code, lots shall be sodded before final at least 10 <br /> feet:around the structure: <br /> 25.A.copy of the energy cacls shall be with permit at all times <br /> 26 Com of rinal.insulation report shall be provided with.permit.before.ihaL <br /> EEE.=Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition. <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National.Electric Code(2011): <br /> t , <br />