Laserfiche WebLink
ing e ami Y W e ing <br /> . :. Plan_ Review Comments. <br /> 1. F.F:E. shall be:a.rriinirnum.of 8".above.�the road elevation and an engineered site plan. <br /> . . <br /> -2.. Lots shall be red.to cw of the-F.B.C._gd o <br /> 3.: :Coinpaction_test required=if 24" or more of fill dirt is brought-in-at any one place: <br /> 4: :Tie in survey required before pouring concrete_. <br /> 5.: Driveways.requi. a R.O.W. :use permit: All 4 sides of driveway.thr i the sidewalk shall have. <br /> expansion material.. :. . <br /> 6. All setbacks.shall,be met.: . <br /> 7.: All.property=markers shall be.uncovered and marked at time of first.inspectiori: <br /> 8:: :All A:D.A:requirements shall be met. . <br /> .9.. No.electric,plumbing,mechanical; or fraining shall be covered without an inspection and <br /> approval first. <br /> 10.-All Garages shall;comply.mith,section R302;6 of the F.B.C.-;(Fire Separation).. <br /> 11..Appliances shall not:be installed in a location where subject to.rriechanical'damage unless <br /> protected by approved barriers. M303.4 of:the F.B:C <br /> 12. Water heaters shall comply with section P607.3 of the F.R.C. <br /> 13. Foundation supports for,A/C units shall be raised at least 3"above finished grade. M1308.1. <br /> 14..Return air in a11.bedrooiris..F.B.C. M1620.4. <br /> 15. Smoke detectors are.to be installed:in accordance with R313:.1 of the.F.B.C. <br /> 16:All glazing requirements-are to be in accordance with R308.4-6f the F.B.C. <br /> 17. All means of egress are to.be in accordance with R311.:of the F.B.G. <br /> 18. `.`Green gypsum.board shall not be used as a backer in showers or tubs:R702:4.2-F.B.C. <br /> 19. Combination-type AFCl breakers are,required at all.locations requiring an AFCI.type breaker: <br /> 20..Carbon monoxide.alarms will be required in new construction that uses fossil-burning.heating' <br /> or appliances or an attached garage.. They shall be installed in accordance with.the R.H.C. <br /> 21. All plumbing,mechanical,-and electrical shall be separate from unit to:unit. This includes all_ <br /> underground plumbing and electric: <br /> 22.'All 2011:N:E:C: Codes:will be enforced.. <br /> 23: Tamper=Resistant Receptacles in accordance with 406.11 'f the 2011 N:E:C <br /> 24:.In accordance..with the Land_Development:Code,lots,shall be,sodded before final-at-least 10 . . . <br /> : <br /> feet around the structure: <br /> 25 A.copy of the enemy cacls shall be with perntitat all times <br /> 26."Copy of fnal.insulation'report shall be.provided with.permit before.fnaL <br /> F.E.E.-Finished Floor-Elevation <br /> F.B.C=Florida Building Code 6 - Edition: <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with-Disabilities Act : N.E.C.-National Electric:Code(2011). . <br />