Laserfiche WebLink
BuildingAnalysis Job: 2575Bsf ADS <br /> Y Date: 10/30/2017 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Design C• • • <br /> Location: Indoor: Heating Cooling <br /> Tampa International AP, FL, US Indoor temperature(OF) 70 75 <br /> Elevation: 10 ft Design TD (°F) 39 16 <br /> Latitude: 28°N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 <br /> Dry bulb(OF) 31 91 Infiltration: <br /> Daily range(OF) - 14 ( L ) Method Simplified <br /> Wet bulb(°F) - 77 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> Component Btuh/ft2 Btuh % of load <br /> Walls 3.8 4204 32.8 ucts <br /> Glazing 30.2 2608 20.3 <br /> Doors 0 0 0 Wall <br /> Ceilings 1.3 1868 14.6 nfiltration <br /> Floors 0 0 0 <br /> Infiltration 1.9 2299 17.9 <br /> Ducts 1846 14.4 <br /> Piping 0 0 <br /> Humidification 0 0 Ceilings <br /> Ventilation 0 0 Glazing <br /> Adjustments 0 <br /> Total 12825 100.0 <br /> Component Btuh/ft2 Btuh % of load <br /> Walls 2.7 3035 16.5 Wall <br /> Glazing ' 52.9 4568 24.8 <br /> Doors 0 0 0 Internal Gains <br /> Ceilings 1.7 2583 14.0 <br /> Floors 0 0 0 <br /> Infiltration 0.4 512 2.8 <br /> Ducts 2137 11.6 <br /> Ventilation 0 0 Glazing <br /> Internal gains 5615 30.4 <br /> Blower 0 0 Ducts <br /> Adjustments 0 Infiltration <br /> Total 18450 100.0 Ceilings <br /> Latent Cooling Load= 3541 Btuh <br /> Overall U-value= 0.083 Btuh/ft2-OF <br /> Data entries checked. <br /> .c g wri htsoft' 2o17-Oct-30 08:11:02 <br /> ACCARight-Suite®Universal 2017 17.0.23 RSU05714 Page 2 <br /> ...A27UHE AH's12575B sf ADS template 1.5-2 ton.rup Calc=MJ8 Front Door faces: W <br />