8138764327 10:16:03 04-23-2018 3/5
<br /> r1U11Ua.nuuulug 11-0=UnHUe Page 2 of 6
<br /> Date Pending FBC Approval
<br /> Date Approved 12/05/2017
<br /> Summary of Products
<br /> Go to Page 0 0 0 Page 3/8 0 0
<br /> PL# Model,Number or Name Description
<br /> 15279.41 041 W5-09 5PO-2F449:Grand Steel Pan(min.24 ga.)with Overlay Single-Car(up,to 9'0"
<br /> Harbor,Stone Manor wide)WINDCODEOD WS Garage Door
<br /> Limits of Use Certification Agency"Certificate
<br /> Approved for use in HVHZ:No Fi]5279 R5 C CAC Letter with proof of contract and proof
<br /> Approved for use outside HVHZ:Yes of inspection.odf
<br /> Impact Resistants N/A FLIS279 R5 C CAC WS Listing rntertek.ndf
<br /> Design Pressure:+30 PSF/-32 PSF Quality Assurance Contract Expiration Date
<br /> Other.The OPTIONAL glazing available for this product 05/21/2028
<br /> meets the wind load requirements of the building code but Installation instructions
<br /> DOES NOT meet the Impact resistant requirement for pLIS279 R5 1I 1035 -RevOS.r)d
<br /> windbome debris regions.The product without glazing DOES Verified By:Intertek Testing Services NA,Inc.
<br /> comply with the Impact resistant requirement for windbome Created by Independent Third Party:
<br /> debris regions(ref 1609.1.4 FBC). Evaluation Reports
<br /> Created by Independent Third Party:
<br /> 1S279.42 IN2 WS-09 W-16899:Reserve Reserve Wood Single-Car(up to 9'0'wide)WINDCODEt9 W5
<br /> Collection RHxx,RRxx,RCxx Garage Door
<br /> Limits of Use Certification Agency Certificate
<br /> Approved for use In HVHZI No P115279 RS C CAC Letter with nroof of contract and oroof
<br /> Approved for use outside HVHZ:Yes of inspgcign,Nd
<br /> Impact Resistants N/A FL15279 R5 C CAC W5 Listing Intertek.odf
<br /> Design Pressure:+32 PSF/-36 PSF Quality Assurance Contract Expiration Date
<br /> Other.The OPTIONAL glazing available for this product 0 5/2 112 0 2 8
<br /> meets the wind load requirements or the building code but Installation Instructions
<br /> DOES NOT meet the Impact resistant requirement for FLIS279 R5 Ii 102466-RevO6.odf
<br /> windbome debris regions.The product without glazing DOES Verified By:Intertek Testing Services NA,Inc.
<br /> comply with the Impact resistant requirement for windbome Created by Independent Third Party: ;
<br /> debris regions(ref 1609.1.4 FBC). Evaluation Reports
<br /> Created by Independent Third Party:
<br /> 15279.43 043 W5-12 AL-IF499:Avantem Full View Aluminum Residential WINDCODE@ W5 Sectional
<br /> Door,up to 122'wide
<br /> Limits of Use Certification Agency Certificate
<br /> Approved for use in HVHZ:No FL15279 R5.C CAC Letter with proof of contract and proof
<br /> Approved for use outside HVHZ:Yes pf!rQM=fon.pdf
<br /> Impact Resistant:NIA ELIS279 R5 C CAC WS Lusting Intertek,odf
<br /> Design Pressure:+32 PSF/-32 PSF Quality Assurance Contract Expiration Date
<br /> Othen The OPTIONAL glazing available for this product 05/21/2028
<br /> meets the wind load requirements of the building code but InsWilation Instructions
<br /> DOES NOT meet the impact resistant requirement for FL15279 RS 11 103445-Rev04.odf
<br /> wlndborne debris regions.The product without glazing DOES Verified By:Intertek Testing Services NA,Inc-
<br /> compiy with the Impact resistant requirement for windbome Created by Independent Third Party:
<br /> debris regions(ref 1609.1.4 FBC). Evaluation Reports
<br /> Created by Independent Third Party:
<br /> 15279.44 044 W5-16 DSIE-1A171:2050, 1-3/11"Double-skin Insulated EPS(exterior skin 27 ga.min.;
<br /> 2051,2053,4050,4051,4053,62, Interior skin 29 ga.min.)Double-Car(92"to 16'0'wide)
<br /> 64,6S,62G,62LG,64G,SDP35, WINDCODEO WS Garage Door
<br /> SFL38,5RP38,134,135,136,
<br /> 6130,6131,6133
<br /> Limits of Use Certification Agency Certificate
<br /> Approved for use In HVHZt No FLIS279 R5 C CAC Letter with proof of contract and Dropf
<br /> Approved for use outside HVHZ:Yes o/inspection.odf
<br /> Impact Resistant:No FLIS 79 RS C CAC W5 Listfna. Intertek.ndf
<br /> Design Pressure:+30 PSF/30 PSF Quality Assurance Contract Expiration Date
<br /> Othen The standard glazing available far this product 05/21/2028 ;
<br /> meets the wind load requirements of the building code but Installation Instructions
<br /> DOES NOT meet the Impact resistant requirement for FL%,5,•279_R5 TI 101595-B-Rev13 ydF
<br /> windbome debris regions. Verified By:Intertek Testing Services NA,Inc.
<br /> Created by Independent Third Party:
<br /> Evaluation Reports
<br /> Created by Independent Third Party:
<br /> 15279.45 045 W5-16 DSIE-1A171:2050, 1-3/8'Double-skin Insulated EPS(exterior skin 27 ga.min.;
<br /> 2051,2053,4050,4051,4053,62, Interior skin 29 ga.min.)Double-Car(9'2"to 16'0'wide)
<br /> 64,65,62G,62LG,64G,SOP38, WINDCODE@ W5 Garage Door
<br /> SFL38,SRP38,134,135,136,
<br /> 6130,6131,6133
<br /> Limits of use Certification Agency Certificate
<br /> Approved for use In HVHZ:No FL15279 R5 C CAC LetKgl with oroof of.contract and Drnp#
<br /> Approved for use outside HVHZ:Yes of inspectign.odf
<br /> hap://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDciv3vWKJZ10... 4/23/2018
<br />
|