Laserfiche WebLink
FORM R405-2017 <br /> - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name. PETBERLLC RES BROWN EPI TJL11 4-18 Builder Name: DON BROWN CONST. <br /> Street: 39165 9TH AVE Permit Office: ZE� rr/��YRHI LLS <br /> City, State, Zip: ZEPHYRHILLS ,FL,33542 Permit Number. �� hl�� <br /> Owner: PETBERLLC RES Jurisdiction: 611600 <br /> Design Location: FL, Tampa County.: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(Fran Plans) 9. Wall Types(1480.0 sgfL) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Bbdt-Int Insul,Exterior R=5.0 1312.00 ftz <br /> b. Frame-Wood,Adjacent R=11.0 168.00 ft= <br /> 3. Number of units,if multiple family 1 c.N/A R=. ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? No 10. CeiTing Types (1808.0 sgft) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1808.00 1`12 <br /> 6. Conditioned floor area above grade(fF) 1808 b.N/A R= ft2 <br /> Conditioned floor area below grade (ft) 0 c.N/A R= f? <br /> 11.Ducts R ftz <br /> 7. Windows(116.0 sgfL) Description Area a.Sup:Attic, Ret Main,AH:Main 6 361.6 <br /> a. U-Factor. Sgl, U=0.30 116.01 ft= <br /> SHGC: SHGC--0.23 <br /> b. U-Facto: WA fP 12. Coding systems kBtu/hr Efficiency <br /> SHGC: a Central Unit 34A SEER:14.00 <br /> c. U-Factor. N/A fiz <br /> SHGC: 13. Heating systems kBtu/hr Efficiency <br /> d. U-Facto WA ft a Electric Heat Pump 32.8 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.333 f. <br /> Area Weighted Average SHGC: 0.230 14. Hot water systems <br /> 8. Floor Types (1808.0 sgft) Insulation Area a. Electric Cap:40 gallons <br /> EF:0.920 <br /> a. Slab-On-Grade Edge Insulation R=0.0 1808.00 ftz b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftz 15. Credits None <br /> Glass/FloorArea: 0.064 Total Proposed Modified Loads: 51.87 PASS <br /> Total Baseline Loads: 55.51 �7 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'LJJE STgl <br /> this calculation are in compliance with the Florida Energy specifications covered by this ti -�' = ,r0 <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. Ja 'r°� <br /> PREPARED BY: Before construction is completed w i <br /> -.... <br /> DATE: y ACZ4g this building will be inspected for , <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> With the Florida Energ o e. Qr(��t� . Op p I <br /> OWNER/AGE T' BUILDING OFFICIAL: <br /> DATE: o DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). <br /> 4/20/201812:28 PM EnergyGauge®USA- FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 <br />