Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1 F.F.E. shall be a minimum of 8" above the road elevation.and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> I Compaction test required if 24" or more of fill dirt is brought in:at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W.use permit. Ali 4 sides of driveway thru the sidewalk shall have <br /> expansion material.. <br /> 6.. All setbacks shall be met.. . <br /> -7. QYl.property:maikers shall be,uncovered and marked at time of first 'inspection: <br /> 8.. All A.D.A. requirements shall be met. . <br /> 9- No electric,plumbing, mechanical; or framing shall be covered without an inspection and <br /> approval first. <br /> 10.-All Garages shall comply-with section R302.6.of the F.B.C:(Fire S:eparation). <br /> 11. Appliances shall'not:be installed in a location where subjectto-rriechariical'darriage unless <br /> ted.by approved barriers. M303.4'of the F.B.0 protec <br /> 12. Water heaters shall co pl ith. section:P607.3 of the F.B.C: <br /> 13. Foundation supports'for A/C units shall be raised at least 3" above finished grade.. M1.308.1 <br /> 14. Return air in all bedrooms.F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed:in accordance:with R313.1 of theRB.C. <br /> 16.'All glazing requirements are.to be in accordance with R308.4.of the.F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C.. :. <br /> 18."Green gypsum board"shall riot be used as.a backer in.showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type A.FCI breakers are required at all locations requiring an AFCLtype breaker: <br /> 20. Carbon monoxide alarms will.be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage: ,They shall be installed in accordance with.the F.B.C. <br /> 21. All plumbing,mechanical,.and electrical shall be separate from unit to.unit. This includes all <br /> underground plumbing and electric: <br /> 22.-All-2011:N:E:C: Codes.will be enforced: <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2011 N:E.0 <br /> 24::In accordance.with the Land Development Code,lots shall be sodded before final at least 10 . . . <br /> feet around the structure. <br /> 25. A.cony of the energy eacls shall be with permit at all times. <br /> 26 Cop of final insulation report shall be provided with pennit before.final: <br /> F.F.E.=Finished Floor Elevation <br /> F.B.C-Florida Building.Code 6t' Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2011) <br />