Laserfiche WebLink
ln Single Famil Dwell <br /> Plan Review-Comments <br /> L F.F:E. shall'be a minimum:of.8"above the road.elevation and an engineered site plan. • ; <br /> 2.. Lots shall be graded.to.comply with R401-.3 of the F.B.C. <br /> 3.: 'Coi�npaetion.test required if 24" or more-of fill dirt is brought in.at any one place: <br /> . <br /> 4:. :Tie in survey required before pouring concrete..' <br /> 5.- Driveways require a R:O:W. use permit: All sides of driveway.thru the sidewalk shall have. <br /> ;expansion material:. :. . <br /> 6.. All setbacks shall be'met.; . <br /> 7.: All property:markers shall be uncovered and marked.at time of first inspection: <br /> .8: .All A.D.A. requirements shall be met.:'- <br /> 9.: No electric;plumbing, mechanical;.or-framing shall be covered without an inspection and <br /> approval first. .. <br /> 10.Ail:Garages shall:comply with,section R302.6:of the.F.B.C.:(Fire Separation).. <br /> 11. Appliances shall iiot.be installed in a location where subjectto.mechanical damage unless <br /> .protected by' approved barriers: M303.4 of.the F.B:C. <br /> 12. Water heaters shall corriply with section:P607,3 of the F.B.C: <br /> 13.;Foundation supports for A/C-units shall b- raised at least 37 above finished grade..' M1308.-1 <br /> 14. Return air in all bedrooms..F.B.C. M.1620.4. <br /> 15. Smoke detectors are to be installed in accordance with:R313:.1 of the:F.B.C. <br /> 16.:All glazing requirements are.to be in accordance with R308.4,of the F.B.C. <br /> .17. All means.of egress are to be in:accordance with-R31.1 of the FiB.C., .: <br /> 18. `.`Green gypsum.board" shall not be used:as.a backer.in showers or tubs. R702.4:2,F.B.C. <br /> 19._Combination-type AFCI breakers.are-required-at all locations requiring an AFCI.type breaker. <br /> 20: Carbon monoxide alarms will be required in new construction.that uses fossil-burning heating <br /> or appliances or-an attached garage:,_They shall be in in accordance with the F.B.C.. <br /> 21. All plumbing,mechanical,:and electrical shall be separate from unit to:unit. This includes all. . <br /> underground plumbing and electric: <br /> 22. All 2011:N.E:C. Codes:will be enforced:. <br /> 23:Tamper= Resistant Receptacles in accordance with 406:11 of the 2011 N.E:C„ <br /> 24: In accordance:.with the Land.Development Code, lots.shall be sodded before final at least 10. . : . <br /> feet:around the structure: <br /> 25. A.copy of the enemy cacls-shall be with:permit at all times. . . <br /> 26 Copy of final insulation�reportshall be.provided with.permit before.fnab <br /> F.F.E.-Finished Floor.Elevation <br /> F.B.C-Florida Building Code 6t',Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act . N.E.C.-National-Electric.Code(2011): <br />