Laserfiche WebLink
- Single. Fami Dwelling <br /> Pl <br /> an Review Comments <br /> l: F.F:E. shall'be a minimum.of.8" above the road.'elevation and an engineered.site plan. <br /> I Lots shall be aded to.corn 1 . with R401.3 of the F.R.C. <br /> gr p Y <br /> 3.: Compaction test required'if 24 or more:of fill dirt is.brought in:at any one place: . <br /> 4.. :Tie in survey required before pouring concrete. <br /> 5.: Driveways:require-a R.O:W. use permit: All 4:sides'of driveway.thru the sidewalk shall have <br /> expansion ma <br /> terial <br /> 6. All setbacks shall be-met. <br /> 7. :All pro shall be.uncovered and marked at time'of first 'inspection: <br /> 8.- :All A.D.A. requirements shall be met. . <br /> .9.. -No:electric,plumbing,mechanical; or framing shall be covered without an inspection.and <br /> approval first. <br /> 10. Ail Garages shall;comply.with.section R302:6;of.the F.B.C.-(Fire Separation).. <br /> 11.Appliances shall not be installed in a location where subject to,mechanical damage unless. <br /> p <br /> rotected'by approved barriers. -M303.4 of the F.B.0 : <br /> .12. Water heaters shall)comply with section.P607.3 of the F.R.C. <br /> 13.Foundation supports-_forA/C.units shall be raised at least 3" above finished grade.. M1308.1. <br /> 14. Return air in all bedrooms..F.B.C. ,M1620.4.- ; <br /> 15. Smoke detectors'are to be installed:in accordance:with R313.1 of the F.B.C. <br /> .16::All glazing requirements are.to be in accordance with R308.4-of the F.B.C. . <br /> 17. All means of egress are to be in:accordance with-R31 Lof the F.B.C. - <br /> 18. '.'Greengypsumboard" shall riot be used as a backer.in showers ortubs.'R702.4.2-F.B.C. <br /> . . <br /> 19.'Combination-type AFCI breakers are.required,at all.locations requiring an AFCI.type breaker: . : <br /> 20. Carbon monoxide alarms will.be re"wired in new construction that uses fossil-burnih heatin <br /> q . g <br /> g <br /> or appliances or an attached garage: They shall be installed in accordance w_ith.the F,B.C:. <br /> 21. All plumbing, mechanical,"and.electrical shall be separate from unit to:unit: This includes all <br /> underground plumbing and electric: <br /> 22.'All2011:N.E:C: Codes will be enforced:. <br /> 23.Tamper= Resistant Receptacles in accordance with 406.11 of the 2011 N:E.0 <br /> 24-An accordance:.with the Land Development:Code; lots.shall be sodded before final at least-10. <br /> feet.around the structure. <br /> 25. A copy of the energy cads shall be'with perntitat all times. <br /> 26. Copy offinal.insulation'r�eport shall be provided with:perm:it before.�na� <br /> F.F.E.=Finished FloorElevation :. <br /> F.B.0 Florida Building Code 6a'Edition <br /> R:O.W-Right.of Way <br /> A.D.A.-Americans with Disabilities Act : N.E.C.-National_Electric:Code (2011). . <br />