Single. Family Dwelling <br /> Plan Review.Comments <br /> 1: F.F.E. shall be a minimum=of.8" above.the road.elevation:and an' engineered site plan. . <br /> I Lots shall be graded.to comply with R401.3 of the F.B.C. . <br /> ;Compaction test required.'if 24 or more:of fill dirt is brought in:at any one place. <br /> 4:. :Tie in,survey required before pouring concrete.. <br /> 5.: Driveways require a R.O.W. use permit.. All 4:sides of driveway.thru the sidewalk shall have. <br /> expansion matenal: <br /> 6.. All setbacks.shall be met:. .' <br /> 7. ;All. .ro ert markers shall be and marked.at time of first inspection: <br /> p p. Y . . .. <br /> .8. All A.D.A:requirements shall be met.: <br /> 9. No:electric blumbing, mechanical..or ThairiinR shall be:covered without an ins ection_and <br /> approval first. . . <br /> 10. All Gara es shall com_1 ..with;section R302:6:of the F.B.C. ire Se.aration . <br /> g p.Y p ). <br /> 11:Appliaiices:shall not:be' installed in.a location where subject to mechanical damage unless <br /> :protected.by approved barriers.-M303.4'ofthe F.B:C. <br /> 12. Water heaters shall comply.with sectionT607.3 of the F.B.C: <br /> 13. Foundation supports for-A/C units hall be raised at least 37 above finished grade, M1308.1 <br /> 14. Return air in all;bedrooms.:F:B.C. .M1620.4,, <br /> 15: Smoke detectors are.to beiristalled iri accordance witli:R313:.L of the:F.B.C. <br /> 16: g.req All glaziri uirements are:.to be in accordance with R308.4 of the F.B:C. <br /> - . <br /> IT A1_l means of egress are to be in:accordance with R311:of the RB.C., <br /> W. 18. `.`Green gypsum board"shall riot be used-as.a backer,in.showers or tubs. R702.4:2.F.B.C. <br /> 19. Combination-type AFCI breakers are required.at all,locations requiring-an AFCI,type breaker: <br /> 20. Carbon monoxide.alarms will.be required in view:construction that uses fossil-burning heating <br /> or appliances of an attached garage... They shall be.installed in accordance with,the F.B.C: <br /> 21. All plumbing, mechanical,:and electrical "shall be separate from unit to:unit: This includes all <br /> underground plumbing and electric: <br /> .22.. All 201YME:C. Codes.will be enforced: <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 N. <br /> 24::In accordance.with the and Development:Code; lots shall be sodded before final at least 10. . . . <br /> feet:around the-structure: <br /> 25.A copy of the energy cacls shall be with:perfnit at all times. <br /> 26. Copy of final insulation report shall be.provided with:pern:it before.rMab <br /> F.F.E.-Finished Floor.Elevation ; <br /> F.B:C Florida Building.Code 6th Edition <br /> R.O.W.-Right of Way. <br /> A.D.A.-Americans with Disabilities Act : N.E.C.-National Electric.Code(2011): <br />