Laserfiche WebLink
Single. Family Dwelling <br /> Plan Review Comments <br /> 1: F.F:E. shall be.a minirnum.of.8"-above the road.elevation:and an engineered site,plan. <br /> 2.. Lots shall be graded.to.comply with R401.3 of the F.B.C. <br /> 3. ;Compactiontest required if 24" or more of fill dirt is.brought in at any one place: .-: <br /> 4:. Tie ini survey required before pouring concrete.' <br /> 5.: Driveways:require a R:O.W. use permit:: All 4sides of driveway thru the sidewalk shall have <br /> :expansion material: <br /> 6.. All setbacks.shall be met... .' <br /> 7.. All property' shall be uncovered and marked at time-of first.iispection: <br /> 8:: :All A.D.A.requirements shall:be met. . <br /> 9.. .No electric;plumbing, mechanical;or framing shall be:covered without an:inspection and <br /> approval first. . <br /> 10.All Garages shall.comply:with section R302:6 ate:F.B.C. Fire -Separation)., <br /> 11.Appliances:shall not:be installed in:a location'Where subjectto_rriechanical damage unless <br /> protected by approved,barriers. M303.4 o£.the F.B.C. <br /> 12. Water heaters shall comply:with sectionT607.3 of the F.R.C. :. . <br /> 13. Foundation supports for A/C units shall be raised at least 3'-' above finished grade. M1308.1. <br /> 14. Return air in all_bedrooms..F.B.C. M1620.4,. . <br /> 15:-Smoke detectors'are.to be instailed:in accordance with:R313:.1 of ihe:F.B.C. <br /> .16:.All glazing requirements-are:.to be in accordance with R308.4.of the F.B.C. <br /> 17. All means.of egress are to:be in:accordance with R3I Y of the F.B.C. . <br /> 18. "Green gypsum.board" shall not be used as.a backer.iii:showers or tubs. R702.44.2.F.B.C. <br /> . <br /> 19._Combination-type AFCI breakers are,required-at all.locations requiring an AFCI,type breaker. <br /> 20: Carbon monoxide.alarins will.be required in.new:construction that uses fossil-burnirigheating <br /> or appliances or ari attached garage: They shall be installed in Accordance''with the F.B.C. <br /> 21. All plumbing,mechanical,:and electrical shalthe separate from unit to:unit: This includes all. <br /> underground plumbing and electric: <br /> 22..'All 2011:N:E.C: Codes will be enforced:. . <br /> 23:Tamper-Resistant Receptacles in„accordance with 406.11 of the 2011 N:E:C <br /> .24::In accordance:with the Land Development-Code; lots.shall be sodded before final at least I0 <br /> feetaround the.structure. <br /> 25.'A.copy of the�nery cacls shall be with:permit at all times. . <br /> 26 Copy of rnal insulatioh report shall be provided with.-permit before.firea� <br /> F:F:E.-Finished Floor Elevation: <br /> F.B:C=.Florida Building Code 6t4 Edition. <br /> R:O.W.-Right.of Way <br /> A.D:A:-Americans with Disabilities Act N.E.C.-National Electric:Code(201 l) . <br />