Laserfiche WebLink
-single. ami we in <br /> Plan Review Comments <br /> 1: F.F:E. shall be a minimum of.8" above'the an road eievation. d an engineered site plan. <br /> 2.- Lots-shall be graded.to comply with R401.3 of the F.B;C:' <br /> 3. ;Compaction_test required if 24" or more of fill dirt is brought in at any.one-place:. . <br /> 4:: :Tie irisurveyrequired before pouring concrete.. <br /> 5.: Driveways:require a R:O:W. use permit:: All.4:sides of driveway thru the sidewalk shall have <br /> expansion material <br /> 6.. All.setbacks.'shall be'inet.:. <br /> :T. A11 property markers shall be.uricovered and marked.at time of first.'inspection: <br /> 8. All A.D.A. requirements.shall be met.: <br /> -9. -No electric,plumbing, echanical or framin shall be covered without an inspection.and <br /> P g,m. <br /> approval <br /> 10..All Garages shall,comply with section R302:6.of.the F.B.C:, (Fire Separation).. <br /> I.:Appliances-shall'not:be installed in:a locationwhere subjectto m6chanica1damdRe unless. „ <br /> rotected b a roved barriers'. M303.4 of the F.B:C <br /> P.. - Y. PP . <br /> 12. Water heaters shall comply with section:.P607.3 of the F.B.C: <br /> 13-. Foundation supports for,A/C.units.shall be raised at least 37 above finished grade. M1308.1 <br /> 14. Return air in all.:b.edrooms. F.B.C. -MI620.4,; <br /> 15. Smoke detectors are.to be installed:in accordance with-R31.3:1 of-the:F.B.C. <br /> .16: All glazing requirements are.to be in accordancewithR308.4'of the F.B.C. . <br /> 17. All means of egress are to:be in.accordance with R31 1.of the F;B.C. <br /> 18. `.`Green gypsum:board shall not be used:as.a backer.jhshowers or tubs.R702.4.2.F.B.C. <br /> 19. Combination-type AFCI breakers are required;at all,locations requiring.an AFCI,type breaker: <br /> 20. Carbon monoxide.alarms Will be required in.new construction that uses fossil-burning heating <br /> or appliances or.an attached garage.- They shall be.installed in accordance with the F,B.C:. <br /> 21. All plumbing, mechanical,.and:electrical shall be separate from unit to unit. This includes all . <br /> underground plumbing and electric: <br /> 22. A11201I N-.E.*C. Codes Will be enforced: . <br /> -23.Tamper=Resistant Receptacles in accordance tivith 406:11 of the2011 N.E:C <br /> 24.:In accordance.with.the Land.Development:Code; lots shall be,sodded before final at least 10 <br /> feet around the structure. <br /> 25 A.cony of the energy cads shall be with permitat all times <br /> 26.--Cony of final insulation mp6rt shall be.provided with permit before.rnab <br /> F.F.E.-Finished Floor.Elevation <br /> F.B:C-:Florida Building Code 6t4 Edition- <br /> R.O.W.-Right of Way. <br /> A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric:Code(2011) <br />