Laserfiche WebLink
Sing e Farm ly.D.welhn <br /> Plan Review.Comments <br /> 1: F.F.E. shall'be;6-minim um' of 8" above.the road.elevation and an engineered site plan. <br /> 2.. -Lots-shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction.test required.if 24" or more:of fill dirt is brought in at any one place: .-. <br /> 4:. 'Tie in survey required before pouring concrete. <br /> 5. . Driveways:require a R.O.W. use permit All 4:sides'of driveway.thru the sidewalk shall have. <br /> expansion material:. <br /> -6. All setbacks.shall be'met: . <br /> 7.: All.property markers shall be uncovered and marked.at time of first.'inspection: <br /> .8. .All A.D.A.requirements shall be met. <br /> 9- No.electric,plumbing, mechanical, or framing shall be.covered without an,inspection and <br /> approval first. <br /> 10. All Garages shall.com_1 :with section R302:6:of.the.F.B.C:: Fire Separation <br /> , g p,Y ( p ) <br /> 11. Appliances shall not be installed in.a location where subject to mechanical damage unless <br /> protectedbyapproved barriers'. M303.4'of the F.B:C <br /> 12. Water heaters shall comply:with section:P607.3 of the F.B.C.- <br /> 13. Foundation supports for'A/C units.'hall-be raised at least 3" above finished grade,. M1308.1 <br /> 14..Return air in all,:bedrooms. F.B.C. M1620.4. <br /> 15. Smoke detectors are.to be:installed.in accordanee:witli:R313:.1 ofthe:F.B.C. <br /> : .16::All glazing requirements are to be'in accordance with R308.4.of the-R&C. <br /> 17. All means of egress are to be in accordance-with R3 I L of the F.B.C. : <br /> 18. `.`Green gypsum board" shall not-be used:as a backer in:showers or tubs. R702.4:2 F.B.C. <br /> 19. Combination-type AFCI breakers are-required-at all,locations requiring an AFCI,type breaker: <br /> 20: Catbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage.. They shall be installed in accordance with the F.B.C:. . <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This-includes all. <br /> underground plumbing and electric. <br /> '22.. All 2011:N:E:C: Codes:will-be enforced: <br /> 23:Tamper- Resistant Receptacles in accordance with 406:11 of the 2011 N:E:C - <br /> 24:.In accordance:with the Land Development.Code,,lots shall be sodded before final at least 10__ <br /> feet.around the.structure: <br /> 25.'A.copy of the enerQp Gaels shall be with permit at all times <br /> '26. Copy of fnal.insulatim report shall be.provided witlz.pernzitbefore.frzab - <br /> T.F.E.-Finished Floor Elevation. <br /> F.B:C-:Florida Building,Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.--Americans with Disabilities Act ' N.E.C.-National Electric Code(2011): <br />