My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19727
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19727
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 1:58:13 PM
Creation date
2/7/2019 1:58:12 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19727
Building Department - Name
LENNAR HOMES LLC
Address
3076 KRESTERBROOKE LANE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 1551B1 sf ADS Carrier <br /> Date: 511/2018 <br /> Entire House By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project Information <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 18777 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.3°F Latent gain: 2492 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21269 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP_ <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 109% of load <br /> Latent capacity: 3600 Btuh 144% of load <br /> Total capacity: 24000 Btuh 113% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 21794 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 18304 Btuh 84% of load Capacity balance: 30 OF <br /> Supplemental heat required: 3490 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 800 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 OF <br /> Meets all requirements of ACCA Manual S. <br /> - wrightso ® 2018-May-01 08:12:20 <br /> M�� ftAv���a� --- ---- Right-Suiteral Universal 2018 18.0.16 RSU05714 <br /> Page 1 <br /> ...equipment\1551 sf ADS template 2ton Carrierrup Calc=MJB Front Door faces:NW <br />
The URL can be used to link to this page
Your browser does not support the video tag.