Laserfiche WebLink
Sing e Faml y Dwe ing <br /> Plan Review Comments- <br /> L. F.F.E. shall be a minimum:of 8"above.the road elevation and an engirieered.site plan. <br /> 2. 'Lots shall be graded to.comply with R401.3 of the F.B.C. <br /> 3. :Compaction:test required.if 24" or more of fill dirt is brought.in:at any one place: . <br /> .4. :Tie in survey-required before pouring concrete.. <br /> 5.: Driveways require a:R.O.:w use permit. All 4sides of driveway thru the sidewalk shall Have. <br /> expansion matenal:. <br /> 6.. A-11 setbacks shall be met.: . <br /> 7. All.property:markers shall be,uncovered and marked.at time of first.ih ection: <br /> 8:. :All A.D.A. requirements.shall be met. <br /> 9.: No electric,plumbing,-mechanical,_or-framing shall be:covered without an,inspection and <br /> approval first. <br /> 10. All Garages shall-comply with,section R302.6 of the F.B.C. (Fire S:eparation).. <br /> 11:Appliances shallnot.be installed in.a location where subject to,mechanical darriage unless <br /> protected by_approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with sectionT607.3 of the F.B.C. <br /> 13. Foundation supports for.A/C.units shall be raised at least 3'.' above finished grade. M1308.1 <br /> 14..Return air in all bedrooms.-F.B.C. M1620.4 <br /> 15. Smoke detecfors-are to be installed in accordance-with:R313:.1 -of the F.B.C. <br /> 16: A11 glazing requirements are..to be in accordance with R308.4.'6f the F.B:C. . <br /> 17. All means.of egress are to:be in:accordance with R311..6f the F.B.C..- <br /> 18. `.`Green gypsum board" shall riot be used as a-backer.in showers or tubs. R702.4:2 F.B.C. <br /> 19. Combination-type AFCI breakers are required,at all,locations requiring An AFCI,type breaker. <br /> .. <br /> 20. Carbon monoxide alarms will.be required in new construction that uses fossil-burning heating <br /> :or appliances-or an attached garage: They shall'be installed'in accordance with,the F.B.C: <br /> 21. All plumbing, mechanical,:and electrical shall.be;separate from unit to.unit: This includes all. <br /> . <br /> underground plumbing and electric. <br /> 22. All 2011.N.E.C, Codes:will be enforced: <br /> .23::Tamper=Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C <br /> .24-An accordance with the Land Development Code,_lots.shall be-sodded before final at least 10 . <br /> feet:around the.structure. <br /> 2S.A.copy of the enerj6 cads shall be with:permitat all times. . <br /> 26. Copy of final.insuktion report shall be.provided with.permit before.fnab <br /> RRE,Finished Floor Elevation <br /> F.B.0 Florida Building,Code 6th Edition <br /> R.O.W.-Right'of Way <br /> A.D.A., Americans with Disabilities Act N.E.C.-National.Electric:Code(2011) . <br />