My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19748
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19748
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 2:08:12 PM
Creation date
2/7/2019 2:08:10 PM
Metadata
Fields
Template:
Building Department
Company Name
ORANGE BLOSSOM RANCH
Building Department - Doc Type
Permit
Permit #
18-19748
Building Department - Name
HOLMES,BARBARA
Address
4538 BLOSSOM BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS <br /> REV DESCRIPTION DATE APPROVED <br /> NOTES: 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD <br /> 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO <br /> REQUIREMENTS OF THE FLORIDA BUILDING CODE. SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. <br /> 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH <br /> RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 <br /> 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND <br /> 4. WHERE SHIM OR BUCK THICKNESS IS'LESS THAN 1-1/2" WINDOW UNITS MUST BE INSTALLATION DETAILS. <br /> ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF <br /> INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND <br /> MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION <br /> 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY DETAILS. <br /> FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY 18. ALL FASTENERS TO BE CORROSION RESISTANT. <br /> BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR <br /> MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN <br /> 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: <br /> A. WOOD: MINIMUM SPECIFIC GRAVITY OF <br /> COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF E=NGTH <br /> B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. <br /> THE ARCHITECT OR ENGINEER OF RECORD, C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. <br /> 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR <br /> PROVIDED. ALUMINUM 6063—T5 FU=30KSI .048" THICK MINIMUM <br /> 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT <br /> EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR <br /> GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". <br /> 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE <br /> OF SUSTAINING APPLICABLE LOADS. <br /> 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. <br /> 11. FRAME MATERIAL: EXTRUDED RIGID PVC. <br /> 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. <br /> 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE <br /> DEBRIS REGIONS. <br /> 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS <br /> WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. <br /> LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. <br /> SIGNED:0610712017 <br /> VIWINTECH 2400 IRVIN WINDOWS <br /> DRIVE <br /> DOORS04N <br /> PADUCAH, KY 42003 `v,•��GENSF,cP <br /> SERIES SL 2100 SH VINYL SINGLE HUNG WINDOW =*• 0,.S961 <br /> W/REINFORCED MEETING & BOTTOM RAILS & STILESE <br /> NOTES <br /> TAT O, FtLr,� <br /> TABLE OF CONTENTS DRAWN: DWG NO. REV ii�0s A,OR10P <br /> SHEET NO. 08 NOTES DESCRIPTION SCALE NTS Q4� 06/06/17 SHEET 1 OF 9 // Ojjj1111�?�\\� <br /> 2 — 5 ELEVATIONS L.ROBERTOLOMASP.E. Luis R. Lomas P.E. <br /> 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 <br /> 6 — 9 INSTALLATION DETAILS 434-688-0609 rll0ln8S@)ltI0Maspe.00M <br />
The URL can be used to link to this page
Your browser does not support the video tag.