Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: R0518244 Builder Name: <br /> Street: 5024 20th St Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: <br /> Owner: Martinez Jurisdiction: 611600 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(846.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 846.00 ft2 <br /> b.N/A R= ft2 <br /> 3. Number of units,if multiple family 1 c, N/A R= ft2 <br /> 4. Number of Bedrooms 0 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (532.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 532.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 532 b. N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(48.0 sqft.) Description Area <br /> a. U-Factor: Dbl,U=0.65 48.00 ft2 <br /> SHGC: SHGC=0.35 <br /> b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 12.0 SEER:16.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: WA ft2 a. Electric Heat Pump 12.0 HSPF:9.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.333 ft. <br /> Area Weighted Average SHGC: 0.350 14.Hot water systems <br /> 8. Floor Types (532.0 sqft.) Insulation Area a. <br /> EF:0.000 <br /> a.Slab-On-Grade Edge Insulation R=0.0 532.00 ft2 b. Conservation features <br /> b. N/A R= ft2 <br /> c.WA R= ft2 15,Credits None <br /> Glass/Floor Area: 0.090 Total Proposed Modified Loads: 20.46 PASS <br /> Total Baseline Loads: 25.12 <br /> I hereby certify that the plans and specifications covered by Review of the plans and itIE A <br /> this calculation are in compliance with the Florida Energy specifications covered b this ti0o N <br /> P 9Y P Y , : `:«�C <br /> Code. calculation indicates compliance, ��' <br /> with the Florida Energy Code. O <br /> PREPARED BY: Before construction is completed w =t,:� { a •- ~ � <br /> DATE: 05-17-18 this building will be inspected for <br /> F <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. I <br /> OWNER/AGENT: (XOUILDING 0 FI IAI <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> 5/17/20181:29 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 4 <br />