Laserfiche WebLink
Single Family_ Y Dwelling _ <br /> Plan"Review-Comments <br /> l: F.F.E. shall he a minirnuin of.8" above.the road elevation and ari engineered.site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the'F.B;C: <br /> 3. :Compaction test required if 24" or more of fill dirt is brought in at any:one place: . . <br /> 4. :Tie in surveyrequired before pouring concrete. <br /> 5. Dnveways`require a R:O:W. use permit:: All 4.sides of driveway.thni the sidewalk shall Have. <br /> expansion material:. <br /> 6. All setbacks shall be-met.: . <br /> 7.: All.property.markers shall be 'uncovered and marked at time of first 'inspection: <br /> 8. All A.D.A. requirements shall be met.: <br /> 9.. No:electric;plumbing,=inechanicaL,or frainirig shall be covered without an.inspection.and <br /> approval first. <br /> 10. All Garages shall:comply:with section R3 02:6,of.the F.B.C..:(Fire-Separation).- <br /> 11.Appliances:shall not:be installed in:a location where subject to mechanical damage unless. <br /> protected by approved barriers: M303.4'of.the RB:C <br /> - . <br /> 12. Water heaters shall comply with section.P607.3 of the F.B.C.- <br /> 13. Foundation supports Tor A/C units shall be raised at least 3" above finished grade.. M 13'08,1 <br /> 14._Return air-in-all;bedrooiris..F.B.C. M1620.4. <br /> -15. Smoke detectors are to be installed in accordance with.R3111 of the.F.B.C. <br /> 16..All glazing requirements are:.to be in accordance with R308.4,of the F.B:C. <br /> 17. A1.1 means of egress are to:be in.accordance with R311 of the F;B.C. :. <br /> 18. `.`Green gypsum board"-shall not be.used as a backer.in-showers or tubs. R702.4:2_F.B.C. <br /> 19. Combination-type AFCI breakers are.required-at all locations requiring.an AFCI,type breaker: <br /> 20. Carbon monoxide.alarms will be required in new construction that uses fossil-burning:heating <br /> or appliances or an attached garage:. They shall be,installed in accordance with the F.B.C.-_ <br /> ,21.'All plumbing,mechanical,.and_electrical shall be separate from unit_fo unit: This includes all, <br /> underground-plumbing and electric. <br /> 22. All 2011:N:E:C: Codes Will.be enforced: . <br /> 23.Tamper=Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C <br /> 24. In accordance with the band Development Code, lots shall be sodded before final at least 10 <br /> feet:around the-structure. <br /> 25. A.copy of the energy cacls-shall be with:permit at all times <br /> 26 COpy of final insulation t eport shall be.provided with.permit-before final <br /> RRE.=Finished Floor Elevation <br /> F.B:C Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric.Code(2011) . <br />