Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Ada 1672 Elev D Builder Name: DRH Express Homes <br /> Street:V�Ts wllrin(�'J Permit Office: <br /> City,State,Zip: Zephyr ills,FL, S3S--�-41 Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: - FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single--iarni-ly a.Concrelb Block-Int Insul, Exterior R='4.1 1372.20 ft2 <br /> b.Frame-Wood,Adjacent R=1 1.0 286.00 f12 <br /> .3. Number of units,if multiple family 1 c.N/A R-' ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area <br /> a.Under Attie(Vented) R=30.0 1572.00 f12 <br /> 6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2 <br /> N/A <br /> Conditioned floor area below grade(ft2) c.) 0 11.Duct R= ft2 <br /> s R ft2 <br /> 7. Windows(182.0 sqft,) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 334 <br /> a. U-Factor: Dbl,U=0.34 142.00.ft2 <br /> SHGC: SHGC=0.31 <br /> - b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6. SEER:14.00 <br /> c.-U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu1hr Efficiency <br /> d. U-Factor: NIA ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.985 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (1672.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None - <br /> c.NIA R= ft2 15.-Credits Pstat <br /> Glass/Floor Area: 0.109 Total Proposed Modified Loads: 56.46 PASS <br /> Total Baseline Loads: 57.14 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 1113ES <br /> this calculation are incompliance with the Florida Energy specifications covered by this 0 <br /> Code.- calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed <br /> CT <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code <br /> OWNER/AGENT: BUILDING OFFICIAL:,.. <br /> DATE: f r DATE:. <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 11/1112017 1:16 PM EnergyGauge@ USA-FIaRes2614 Section R405.4.1 Compliant Software Page 1 of 4 <br />