Laserfiche WebLink
Job: <br /> wrightsoftt' Project Summary Date: Oct 10,2014 <br /> Entire House By: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> -V%ro e zftf R 16t,6,tmatloh-�; .-,--,,,.. ,.,'.. A <br /> For: DR Horton/Express Homes <br /> Lot 28 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> Notes: <br /> NI't - • iln5ftnati6n' <br /> Weather: Tampa Intl AP, FL, US. <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 16693 Btuh Structure 16082 Btuh <br /> Ducts 3619 Btuh Ducts 5114 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> PIPIP9, , 0 Btuh <br /> Equipment load 20312 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 21197 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2231 Btuh <br /> Ducts 646 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heatin Cooling (none) <br /> Area(ft2) 1M 1647 Equipment latent load 2877 Btuh <br /> Volume(ft3) 14494 14494 <br /> Air changes/hour 0.26 0.14 Equipment total load 24074 Btuh <br /> Equiv.AVF (cfm) 63 34 Req.total capacity at 0.75 SHR 2.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> -Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model- CH14NB030****A Cond CH14NB030****A <br /> ,AHRI ref Coil FB4CNP030 - <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh @ 47OF Latent cooling 7500 Btuh <br /> TdmDerature rise- 27 OF Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh' <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=31 OF <br /> Backup: <br /> Input=6kW, Output=21934Btuh, 100AFUE <br /> Calculations approved by ACCA to meet'all requirements of Manual J 8th Ed. <br /> :03 <br /> 4wrilghtsofV Right-Suite®Universal 2017 ITOM FiSU25554 Pa 2017-Nov-11 1'3:18ge I <br /> ...onWrightsoit Files\Express hornes\Aria 4EA9.rup Cale=MJ8 House faces: E- <br />