Laserfiche WebLink
FLORIDA ENERGY EFFICIENCY CODE <br /> FOR BUILDING CONSTRUCTION <br /> Envelope Leakage Test Report <br /> Prescriptive and Performance Method <br /> Project Name: SILVERADO Builder Name: D R HORTON <br /> Street: 6541 Wagon Trail St Permit Office: <br /> City,State,Zip: Zephyrhills,FL 33541 Permit Number: <br /> Design Location: 6541 Wagon Trail St(Lot 24) Jurisdiction: <br /> Cond.Floor Area: 2605 Cond.Volume: 21613 <br /> Envelope Leakage Test Results Leakage Characteristics <br /> Regression Data: <br /> C: n: R: <br /> CFM(50): 2389 <br /> Sin le or Multi Point Test Data <br /> ELA: 131 <br /> HOUSE PRESSURE FLOW: <br /> EgLA: 311 <br /> 1 50 Pa 2389 cfm <br /> ACH: 6.63 <br /> 2 0 Pa 0 cfm <br /> SLA: .05 <br /> 3 0 Pa 0 cfm <br /> ACH(50)`: 6.63 <br /> 4 0 Pa 0 cfm <br /> `For prescriptive projects,tested leakage must be<=7 <br /> 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage <br /> must be<=the ACH(50)shown on Form R405-2014 <br /> 6 Pa cfm for this project. <br /> R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 <br /> and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in <br /> Section 553.993(5)or(7),,Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the <br /> results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all <br /> penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration <br /> 3.Interior doors,if installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> I hereby certify that the above envelope leakage performance results <br /> demonstrate compliance with Florida Energy Code requirements in <br /> accordance with Section R402.4.1.2. <br /> Testing shall be conducted by either individuals as <br /> defined in Section 553.993(5)or(7), Florida Statutes p4T Sr�TF <br /> or individuals licensed as set forth in Section <br /> qi,. a,as <br /> 489.105(3)(f),(g),or(i)or an approved third party.A <br /> written report of the results of the test shall be signed <br /> Di itally signed by Michael by the third party conducting the test and provided to ? <br /> g i <br /> Silberstein the code official. ° r <br /> Date:2018.11.29 14:58:31 EST <br /> CN=Michael Silberstein,O=TopBuild O <br /> Home Services,OU, '0 1YE <br /> EMAI LADDRESS=Michae I.Silberstei <br /> Signature: n@topbuild.com,C=US <br /> Michael Silberstein BUILDING OFFICIAL: <br /> Printed Name: Q <br /> Date: 11/29/2018 DATE: 12- V <br /> Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. <br /> 10/2512017 410401 <br />