My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19796
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19796
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 2:44:07 PM
Creation date
2/7/2019 2:44:05 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19796
Building Department - Name
DR HORTON INC
Address
6533 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pt SummaryD <br /> Wrights®ft�' ro Project Date: Oct 10,2014 <br /> Entire House y <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct, Port Richey,FL 34668 Phone:,727-847-3898 Fax:7277815-3399 License:CAC033669 <br /> • • • <br /> For: DR Horton/ Express Homes - <br /> Lot 23 Blk 6 Silverado Ranch, Zephyrhills, FL <br /> Notes: <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity .50 % <br /> _ Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 19683 Btuh Structure 21465 Btuh <br /> Ducts 6943 Btuh Ducts 9394 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 26626 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 30859 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces- 0 Structure 2781 . Btuh <br /> Ducts 1569 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2 2845 2845 Equipment latent load 4350 Btuh <br /> Volume(ft3) 23685 23685 <br /> Air changes/hour 0.22 0.11 Equipment total load 35209 Btuh <br /> Equiv.AVF (cfm) 87 43 Req.total capacity at 0.75 SHR 3.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB042****A Cond CH14NB042****A <br /> AHRI ref Coil FB40NP042L <br /> AHRI ref <br /> Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 30000 Btuh <br /> Heating output 41000 Btuh @ 47°F Latent cooling 10000 Btuh <br /> Temperature rise 27 OF Total cooling 40000 Btuh <br /> Actual air flow 1367 cfm Actual air flow 1367 cfm <br /> Air flow factor 0.051 cfm/Btuh Air flow factor 0.044 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=31 OF <br /> Backup: <br /> I nput=9.kW, Output=29290 Btuh, 100 AFU E <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> WI'1 I7tSOfC" 2017-Nov-1112:33:02 <br /> �� g Right-Suite®Universal 2017 17.0.21 RSU25554 Pagel <br /> ..es\Express homes\Elie 4EJB-3.5 ton New Code.rup Calc=MJ8 House faces:NE <br />
The URL can be used to link to this page
Your browser does not support the video tag.