Laserfiche WebLink
Sin9 Je Family Dwelling. <br /> Pl <br /> an Review Comments <br /> 1: E.F.E. shall be a minimum of 8" above-'the road elevation and an engineered site_plan. <br /> 2.- Lots shall be-graded.to comply with R401.3 of the-F.B;C: .. . <br /> 3. Compaction:test required if 24" or more of fill dirt is brought in at any one place'.,'. <br /> 4.. :Tie in survey required before pouring concrete. <br /> 5.. Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall Have. <br /> :expansion material. <br /> 6.' All. setbacks shall be inet.:. <br /> T All property markers shall be,uncovered and marked at time'of first inspection. <br /> 8.. :Ail A.D.A.-requirements shall be met. . <br /> 9.. No electric;plumbing,mechanical; or framing shall be covered without an inspection_and <br /> approval first. <br /> 10. All Garages shall;comply;with section R302.6 of the:F.B.C. (Fire Separation). <br /> 11:Appliances:shallnot be installed in.a location where subject to mechanical damage unless <br /> protected by approved:barriers. M303.4 of.the RB:C <br /> 12. Water.heaters shall comply:with section:P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C.units.shall be raised at least 37 above finished grade.. M 1308.1 <br /> 14. Return air in all.;bedrooms. F.B.C. .M.1620.4. <br /> 15: Smoke detectors'are to bd installed in-accordance:with:R313.1 of the:F.B.C. <br /> 16: All glaz.ing requirements are_to be in accordance with R308.4,of the F.B.C. <br /> „ <br /> 17. All means.of egress are to be in.accordance with R31 Lof the F:B.C. - <br /> 18. `.`Green gypsum board"-shall not be used as a backer in:showers or.tubs.R702.44:2.F.B.C. <br /> 19. Combination-type AFCI breakers are required:at all locations requiring an AFCI,type breaker: , <br /> 20.,Carbon monoxide,alarins will.be required in new construction that uses fossil-burning-heating <br /> :or appliances or an attached garage:- They shall be-installed iri accordance with the F.B.C:. <br /> 21. All plumbing,mechanical,and:electrical shall be separate from unit.to unit. This includes all. <br /> underground plumbing aril electric: <br /> 22. All 2011:N:E:C: Codes.will be enforced-..*.' ... <br /> ..23.;Tamper- Resistant Receptacles in accordance with 466.11 of the 26'11 N-.E:C <br /> 24:.Iri accordance:.with the Land Development:Code,dots.shall be sodded before final of leash 10 , <br /> feet::around the structure. <br /> 25.A.cony of the enerQ-y cacls-shall be with:bermit at all times. <br /> 26 Cony of final.insulatioh report shall be.nrovided with nernait before riizaL .- <br /> F.F.E.=Finished Floor Elevation <br /> F.B.C=_Florida Building Code 6a'Edition: <br /> R.O.W.-Right.of Way <br /> A.D.A.-Americans with.Disabilities Act ' N.E.C.-National Eleotric.Code(2011) <br />