Laserfiche WebLink
Manual S Compliance Report Job: 2575A1 sf ADS Carrier <br /> p p Date: 5/1/2018 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project Information <br /> For: Lennar Homes <br /> Gooling 'Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 17587 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.2°F Latent gain: 3487 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21074 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 116% of load <br /> Latent capacity: 3600 Btuh 103% of load <br /> Total capacity: 24000 Btuh 114% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 32.1°F Heat loss: 12527 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 24000 Btuh 192% of load Capacity balance: 17 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 of <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 3.5 kW 94% of load Temp. rise: 50 °F <br /> i <br /> Meets all requirements of ACCA Manual S. <br /> ® wrightsoft® 2018-May-0109:15:16 <br /> �� • .,r wwh-��-o , Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> /ICCA g <br /> ...ment�2575A sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces:NW <br />