My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19804
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19804
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2019 8:30:54 AM
Creation date
2/8/2019 8:30:52 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19804
Building Department - Name
LENNAR HOMES LLC
Address
3112 KRESTERBROOKE LANE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 2889A1 sf ADS Carrier <br /> p p Date: 51112018 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project Information <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 92.4°F Sensible gain: 13429 Btuh Entering coil DB: 75.8°F <br /> Outdoor design WB: 77.4°F Latent gain: 2649 Btuh Entering coil WB: 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 16078 Btuh <br /> Indoor RH: 50% Estimated airflow: 600 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> ,Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Sensible capacity: 15300 Btuh 114% of load <br /> Latent capacity: 2700 Btuh 102% of load <br /> Total capacity: 18000 Btuh 112% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 10946 Btuh Entering coil DB: 69.60-F <br /> Indoor design DB: 70.0°F <br /> I ' <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Output capacity: 13453 Btuh 123% of load Capacity balance: 20 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 600 cfm <br /> Output capacity: 3.1 kW 98% of load Temp. rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> -�- wrightsoft- 2018-May-01 13:32:55 <br /> Right-Suite®Universal2018 18.0.16 RSU05714 <br /> �CI� Page 2 <br /> ...ent\2889A1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces:NW <br />
The URL can be used to link to this page
Your browser does not support the video tag.