Laserfiche WebLink
Single Family Dwelling <br /> P <br /> lan Review Comments . . <br /> 1: F.F.E. shall be a minimum of 8. above.the road elevation_and an engineered.site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. .: . <br /> 3.: :C6mpaction west tequired if 24" or more=of fill dirt is brought in:at any one place: - <br /> 4.. :Tie in survey required before pouring concrete.. <br /> 5.. Dnveways:require a R.D.W. use permit: All 4.sides of driveway thru the sidewalk shall Have. <br /> :expansion matenal.. <br /> 6.. -All setbacks.shall be met.:. <br /> 7. All_property:markers shall be uncovered and marked at time of first inspection: <br /> .8. :All A.D.A.-requirements shall be met. . <br /> 9. -No electric plumbing <br /> , mechanical;-or framing shall be covered without an;inspection and <br /> approval first. . <br /> 10..All,Garages shall,c6mply:mith;section R302.6:of the F.B.C...(Fire S:eparation). <br /> 11:Appliances shall-not:be installed in,a location where sulij ect to`mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.C. <br /> 12. Water heaters shall_comply:with section:P607.3 of the F.B.C. <br /> 13. Foundation supports for-A/C.units shall be raised at least 3'.' above finished grade.. M1308.1 <br /> 14..Retum air'in-all,bedrooihs.-F.B.C. ,M1620.4.. <br /> 15::Smoke detectors are.to be installed:in-accordance with'R313:.1 of the.F.B.C. <br /> .16: All glazing requirements are'.to be in accordance'with R308.4.of the F.B.C. <br /> 17. All means.of egress are'to be in:accordance with R311:of the F.A.C. <br /> 18. "Green gypsum board" shall not be used:as.a backer in showers or tubs:R702.462 F.B.C. <br /> 19.Combination-typeA.FCI breakers are.required:at all.locations requiring an AFCLtype breaker: <br /> 20: Carbon monoxide alarms will.be required in new.construction that uses fossil-burning heating <br /> :or appliances or an attached garage:. They shall be.installed in accordance with.the F.B.C.. <br /> 21. All plumbing,mechanical, and:electrical shall be sepatate from unit to unit: This includes all, <br /> underground plumbing and electric. <br /> 22. All 2011.N:E.E. Codes:will.be enforced: <br /> 23:-Tamper-Resistant Receptacles in accordance with 406.11-of the 2011 N:E:C <br /> 24: In accordance:.with the Land.Development:Code;lots shall be.sodded'before final at least 10. . <br /> feet:around-the.structure. <br /> 25.A copy of the ener,6 Gaels shall be with permit at all times. <br /> 26. Copy of final.insulation'reportsliallbe.provided with.permitbefore-finA <br /> .F.E:-Finished Floor Elevation_ <br /> F.B.C=Florida Building Code 04 Edition- <br /> R.O.W.-Right.of Way <br /> A.D:A:-Americans with Disabilities Act N.E.C.-National Electric Code(2011): <br />