Manual S Compliance Report Job: 2575B1 sf ADS Carrier <br /> Date: 5/1/2018 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 17888 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 3041 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 20929 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 114% of load <br /> Latent capacity: 3600 Btuh 118% of load <br /> Total capacity: 24000 Btuh 115% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 12825 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 24000 Btuh 187% of load Capacity balance: 16 of <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> * wrightsoft® 2018-May-01 13:57:59 <br /> R. ,a-�.w�,..n�P Right-Suite®Universal 2018 18.0.16 RSU05714 <br /> Page 2 <br /> AGCK ..ent\25758 sf ADS template 1.5-2 ton Carrier.rup Cale=MJ8 Front Door faces:NE <br />