Laserfiche WebLink
Sin le Famll Dwelhn <br /> Y g <br /> Plan Review Comments <br /> 1: F.F:E. shall be a.minimum.of.8",above"the road elevation and an engineered site plan. <br /> -2. Lots-shall be-graded to,comply with R401.3 of the F.B,C: <br /> 3. Compaction test required if 24"-or more of fill dirt is.brought in=at any one place:. - <br /> 4. 1 Tie in survey required before pouring concrete. <br /> 5. Driveways.require a R:O.W. use permit:. All 4.sides of driveway thru the sidewalk shall have <br /> expansion material: <br /> 6.. All setbacks.shall be met.:. . <br /> 7.: All property markers shall be. 'uncovered and marked.at time'of first inspection: <br /> 8:. All A.D.A. requirements shall be met. . <br /> 9. No:electric; plumbing, mechanical; or framing shall be:covered without an inspection and <br /> approval first.. <br /> 10. All Garages shall:comply with:section R302:6 of,the F.B:C:.(Fire Separation).. <br /> 11.Appliances:shall not:be installed in a location where subject to.mechanical darnage unless <br /> protected:byapproved barriers-. -M303.4 of the F.B:C :. <br /> 12. Water heaters shall comply:with section P607.3 of the F.B.C: <br /> 13. Foundation supports for.A/C.units shall-be raised at least 3" above finished grade.. M1308.-1 <br /> 14.Return air in all_bedrooins. F.B.C. .M-1620.4 <br /> 15.Smoke detecfors are to be iristailed:in accordance.with:R313:1 of the:F.B.C. <br /> 16.:.All glazing re q uironients are:.to be in accordance with R308'A of the F.B.C. ... <br /> IT All means of egress are to:bein accordance with R31.1 of the RB.C., :. <br /> 18. `.`Green gypsum board" shall not be used as a backer.in showers or tubs. R702.4:2.F.B.C. <br /> 19. Combination-type A.M.breakers are,required at all locations requiring an AFCI type breaker: <br /> 20:-Carbon monoxide alarms will be required in.new construction-that uses fossil-burning heating <br /> or appliances or art attached garage.: They shall be,installed in accordance with.the RB.C: <br /> 21. All plumbing,mechanieal,:and_electrical shall be separate from unit.to:unit: This includes all. . <br /> underground plumbing and electric: <br /> 22. All 2011.N.E:C: Codes.Will.be enforced:. <br /> .23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 ME:C <br /> 24.:In accordance with the Land:Developmeht:Code. lots.shall be,sodded before final at least 10. . <br /> feet.around the.structure: <br /> 25 A.tour of the energy cacls shall be with wern:it at all times <br /> 26 Copy of final insulation report shall be.provided with-Pernnit before finab . <br /> F:F.E:-Finished Floor Elevation. <br /> F.B:C-Florida Building,Code 6t':Edition <br /> R.O.W.-Right of Way - <br /> A.D.A.-Americans-with Disabilities Act , N.E.C.-National Electric Code(2011) <br />