Laserfiche WebLink
Buildin Anal SIS Job: 1941B1 sf ADS Carrier <br /> g Y Date: 5/1/2018 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Tampa International AP, FL, US Indoor temperature(°F) 70 75 <br /> Elevation: 10 ft Design TD ff) 39 16 <br /> Latitude: 28°N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 <br /> Dry bulb(°F) 31 91 Infiltration: <br /> Daily range(°F) - 14 ( L ) Method Simplified <br /> Wet bulb ff) - 77 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> MEN M, <br /> Component Btuh/ftz Btuh % of load <br /> Walls 5.6 7036 25.5 Uas <br /> Glazing 30.2 4709 17.0 wa10ther <br /> Doors 23.5 466 1.7 nfiltration <br /> Ceilings 1.3 = 2429 8.8 <br /> Floors 3.5 6726 24.3 <br /> Infiltration 2.1 3056 11.1 <br /> 6 Ducts 3221 11.7 <br /> Piping 0 0 Glazing Floors <br /> Humidification 0 0 <br /> ,.Ventilation 0 0Ceilings <br /> Adjustments 0 <br /> Total 27641 100.0 <br /> Component Btuh/ftz Btuh % of load <br /> Walls 2.8 3500 13A walls <br /> Glazing 56.7 8852 33.2 Internal Gains <br /> Doors 18.4 365 1.4 <br /> Ceilings 1.7 3358 12.6 <br /> Floors 0 0 0 <br /> Infiltration 0.5 684 2.6 <br /> Ducts 3628 13.6 <br /> Ventilation 0 0 Glazing Ducts <br /> Internal gains 6240 23.4 <br /> Blower 0 0 Infiltration <br /> Adjustments 0 <br /> Total 1 1 26627 100.0 Other Ceilings <br /> Latent Cooling Load= 3680 Btuh <br /> Overall U-value= 0.103 Btuh/ftz-°F <br /> .Data entries checked. <br /> =ightsc ft- 2018-May-01 12:35:12 <br /> ^�^ w^- Right-SuRe®Universal2018 18.0.16 RSU05714 Page 1 <br /> ..equipment\1941 sf ADS template 3ton Camer.rup Cale=MJ8 Front Door faces:NE <br />