My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19809
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19809
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2019 8:36:50 AM
Creation date
2/8/2019 8:36:48 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19809
Building Department - Name
LENNAR HOMES LLC
Address
3088 KRESTERBROOKE LANE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Single Family Dwelling <br /> Plan Review.Comments- <br /> 1: F.F:E. shall be,a.minimum of.8"above the road.elevation and an engineered site plan. <br /> 2. .Lots shall be graded.to comply with R401.3-of the F.B:C. <br /> 3. .Compaction.test required if 24" or more of fill dirt is-brought in at any one place: <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R:O.W.use permit: All 4:sides of driveway thru the sidewalk shall.have. <br /> expansion material: <br /> 6..' All setbacks shall be met. . <br /> 7. Allp rop ert markers shall be un ,covered and�marked at time of first.inspection;,. . Y . . <br /> 8: :All A.D.A. requirements shall be met. . <br /> 9. No:electric,plumbing,,mechanical;.or framing shall be covered without an inspection and <br /> approval first.. <br /> 10. All Garages shall comply:with section R302:6.of the.F.B.C.-(Fire Separation). <br /> 11.,Appliailces.sha.11'hot.be installed i.n a lodation'whdre siibjectto.mechanical-damage unless <br /> protected byapproved barriers. M303.4 of the F.B:C. <br /> 12. Water heaters shall comply with section.P607.3 of the.F.B.C: <br /> 13. Foundation supports for A/C.units shall be raised at least 3'.'above finished grade. M1308.1 <br /> . Return air in all.bedrooms. F.B.C. .M.1620.4.. <br /> 15..Smoke detectors'are to be installed:in accordance:with:R313:.1 oftheT.B.C. <br /> 16. All glazing requirements are:.to be in-accordance with R308:4.of the F.B.C. <br /> 17. All means of egress-are to be in:accordaiice with R311:of the F:B.G., <br /> 18. `.`Green gypsum board shall not be'.used:as.a backer.irishowers or tubs. R702.4.2.F.B.C. <br /> 19.'Combination-type AFCI-breakers'are,requited.af all locations requiring-an AFCI,type breaker: <br /> .20. Carbon monoxide alarms-Will.be required in.new:construction that uses fossil-burning heating <br /> -or appliances or an attached garage. They shall be.installed in accordance with.the F.B.C. <br /> 21. All plumbing,mechanical,:and_electrical shall.be separate from unit to.unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2011:N:E:C: Codes will-be enforced:. <br /> .23.Tamper=Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C <br /> 24. In accordance with the Land.Development:Code, lots.shall be,sodded before final at least 10. . <br /> feet:around the.structure: <br /> 25. A copy of the energy cacls shall be with permit at all times. :. <br /> 26 Copy of final insulation mportshall be.provided with permit before final <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C=Florida Building Code'6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with:Disabilities Act : N.E.C:-National Electric.Code(2011): . <br />
The URL can be used to link to this page
Your browser does not support the video tag.