My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19822
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19822
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2019 10:42:21 AM
Creation date
2/8/2019 10:42:20 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-19822
Building Department - Name
MACDONALD,ALFRED
Address
5146 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> gineering&Testing Inc. <br /> 19530 Ramhlewood Drive <br /> Humble,T1,77338 <br /> Code Compliance: The product described herein has demonstrated compliance with <br /> The Florida Building Code 2017,Section 1504.3.2,1504.7. <br /> Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load <br /> requirements of the Florida Building Code 2017,as relates to Rule 61G20-3. <br /> Performance Standards: The product described herein has demonstrated compliance with: <br /> ■ UL 580-06-Test for Uplift Resistance of Roof Assemblies <br /> m UL 1897-2012-Uplift Test for Roof Covering Systems <br /> ■ FM 4471-Foot Traffic Resistance Test <br /> Reference Data: 1. U L 580-06/1897-04 Uplift Test <br /> Force Engineering&Testing,Inc.(FBC Organization#TST-5328) <br /> Report No.476-016OT-12 <br /> 2. FM 4471-10,Foot Traffic Resistance Test <br /> Force Engineering&Testing,Inc.(FBC Organization#TST-5328) <br /> Report No.476-016OT-12 <br /> 3. Certificate of Independence <br /> By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc. <br /> (FBC Organization#ANE ID:1920) <br /> Test Standard Equivalency: The UL 1897-04 test standard is equivalent to the UL 1897-2012 test standard. <br /> The FM 4471-10,Foot Traffic Resistance test standard is equivalent to the <br /> FM 4471-92,Foot Traffic Resistance test standard <br /> Quality Assurance Entity: The manufacturer has established compliance of roof panel products in <br /> accordance with the Florida Building Code and Rule 61G20-3.005(3)for <br /> manufacturing under a quality assurance program audited by an approved <br /> quality assurance entity. <br /> Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017,including Section <br /> 1507.4.2 and in accordance with Manufacturers recommendations. For slopes <br /> less than 3:12,lap sealant must be used in the panel side laps. <br /> Installation: Install per manufacturer's recommended details. <br /> ®,0��411111f!!�!I <br /> No.449 <br /> '6• STATE OF ;a <br /> ice•' � • <br /> �Du,Ais .Ora114So,G+�. <br /> FL#15837.2 R2 August 7, 2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.