Laserfiche WebLink
NFPA 72, Chapters.:I ,2 3 ;4` 5 6 7 8 A.0 11 (circle all that apply) -2- <br /> NFPA 70,National Electrical Code,Article 760 <br /> 'k Manufacturer's instructions <br /> Other(specify): <br /> Signed: — -Date: Org.: f C- <br /> ' i <br /> 3. Record of System Operation <br /> Documentation in accordance with Inspection Testing Form,Figure 10.6.2.3 is attached: <br /> All operational features and functions of this system were tested by (_t- <br /> on ( %. ` I' ; and found to be__operating properly in accordance with the requirements of: <br /> NFPA 72, Chapters :1,_ 2 34' S ;6 -.7, 8 10 11 (circle all that apply) <br /> NFPA 70,National Electrical Code,Article 760 <br /> Manufacturer's Instructions <br /> Other(specify): <br /> Signed: - Date: ' f ;..} `/ Org: <br /> (Chapters: I—Admin., 2—Referenced Pubs, 3—Definitions, 4-Fundamentals, 5—Initiating Devices, 6—Protected <br /> Premises, 7—Notification Appliances, 8—Supervising Station, 10—Inspecting& Testing, 11—Household Alarms) <br /> 4. Signaling Line Circuits: <br /> Quantity and Class (See NFPA 72, Table 6.6.1) of signaling line circuits connected to system <br /> Quantity: Style: Class: <br /> 5. Alarm Initiating Devices and Circuits(Use blanks to indicate quantity of devices) <br /> Quantity and Class of Initiating Device Circuits(NFPA 72 Table 6.5): <br /> Quantity: Style: Class: <br /> MANUAL <br /> a) Manual Stations: Noncoded Addressable: Transmitters: <br /> b) Combination Manual Fire Alarm and Guard's Tour Coded Stations: <br /> AUTOMATIC <br /> Coverage: Complete: Partial: Selective: Non-Required: <br /> a) Smoke Detectors: Ion: Photo: Addressable: <br /> b) Duct Detectors: Ion: Photo: Addressable: <br /> c) Heat Detectors: FT: RR: FT/RR: Addressable: <br /> d) Sprinkler Water Flow Switches:Noncoded,: Transmitters: Addressable: <br /> e) Other(list): <br /> 6. Supervisory Signal Initiating Devices and Circuits(Use blanks to indicate quantity of devices) <br /> SPRINKLER SYSTEM ENGINE DRIVEN FIRE PUMP <br /> a) Valve Supervisory Switches h) Selector in Auto Position <br /> b) Building Temperature Points k) Selector in Auto Position <br /> c) Site Water Temperature Points i) Engine or Control Panel Trouble <br /> d) Site Water Supply level Points D Fire Pump Running <br /> ELECTRIC FIRE PUMP ENGINE DRIVEN GENERATOR <br /> e) Fire Pump Power 1) Control Panel Trouble <br /> f) Fire Pump Running m) Transfer Switches <br /> g) Phase Reversal n) Engine Running <br /> Other Supervisory Function(s)(specify): <br /> 7. Annunciator(s): Qty: 1 Type: Location: <br /> 8. Alarm Notification Appliances and Circuits: <br /> For Emergency Voice/Alarm Service: <br />