Laserfiche WebLink
Snow Load 31-40 psf <br /> Modules in Landscape <br /> VNind Speed Exposure 2:12 c Roof Pitch c 612 7:12 c Roof Pitch-<12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3' Zone 1 Zone 2. Zone 3 <br /> B 59 <br /> 85 mph 110 mp_h C .67 42 <br /> D 56: 35 <br /> B 54 <br /> 90 mph 115 mph C 61 38 <br /> D 51 32 <br /> B 45 <br /> 100 mph_ 125 mph' C 5 I 32 <br /> D 74 -" 43 27 <br /> (3 57 36 <br /> 110 mph 140 mph C 70 41 26 <br /> D 59 34 22 46. <br /> B' 50- 31 <br /> 120 mph 150 mph C 61 3$ 22 47 47" <br /> D 51 . 30— . -- 19 49. 40 40 . <br /> Notes: <br /> Spacing Govemed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing In Inches for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to meet appropriate rafter spacing <br /> 2:)Maximum allowed spacing approved by EcoFasteri Solar is 72" <br /> 3.)Maximum allowed standoff.capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of40" <br /> 0.)Based'on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering Is included in this table <br /> Snow Load 31-40 psf <br /> Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12 c Roof Pitch c 12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone.2 Zone 3 <br /> 85 mph 110 mph C 38- 24 <br /> _ - - D 32 _20 <br /> B 49 30 <br /> 90 mph 115 mph C 35 22 <br /> D 29 18 <br /> 100 mph 125 mph C i 29 18 <br /> - - - -- D 42, 26 -15 - <br /> _ B 33 20 <br /> 110 mph 140 mph C 40 23 14 <br /> D 34 19 12 26 26 <br /> B 49 26 18 <br /> 120 mph 150 mph l C 35 20 12 27 `27 <br /> D .__. 29_ 17__ 10 22 <br /> —Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in Inches for pullout forces only on EcoFasten Solar standoff <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module length of 70" <br /> 6.)Based on Risk Category If(ASCE 7-16)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is Included In this table <br /> wwwecofastensolar.com info@ecofastensolar.com 977-859-3947 10 <br />